HomeMy WebLinkAboutOrdinances 303 ►. r ��, i 1 i • •
ORDINANCE NC
AN ORDINANCE regulating the plumbing, ventilating and
drainage of buildings, and to provide for the registration of plum-
bers, and repealing Ordinance No. lf3t , and all amendments thereto,
and. all Ordinane€s in conflict theitiath, and declaring an emergency.
THE CITY OF CENTRAL POINT DOTE ORDAIN AS FOLLONS:
Section 1, No person snail hereafter erect or cause to be
erected or convert any building to a new purpose, by alteration, by
addition or otherwise, so that it or any part thereof shall be in-
adequate or defective in respect to plumbing, ventilating or sewerage,
or any other usual, proper or necessary provisions or precautions for
the security of life or health, nor shall any owner, builder, lessee,
tenant or occupant of any building or structure cause or allow any matter
or anything to be done in or about any such building or structure dan-
gerous or prejudicial to life or health.
REGISTRATION OF PLUMBERS
Every person engaged in the plumbing business in the City of
Central Point as a master plumber shall appear in person at the office
of the inspector of plumbing and register his name and business address,
upon forms prescribed by the board of examiners, upon presenting satise.
factory proof that he is a bona fide master plumber, and no person
other than a registered plumber, havirc- an established plumbing shop,
shall be allowed to carry on or engage in the plumbing business or
make any connection with any Newer, drain, soil, waste or water pipes
connecting therewith.,
PERMITS
No connection shall be made with any sewer, drain, soil, waste
or water pipes connecting therewith, until a plumbing permit therefor
shall have first been obtained from the plumbing inspector's office and
a fee paid therefor of one dollar (4pl.00) , provided that in the event
of a building permit hes been previously issued for the construction of
premises at a cost of three thousand dollars ($3000.00) or more, no fee
shall be charged. The plumbing permit hereinbefore mentioned shall be
kept posted in a conspicuous place on the premises where work is to be
performed.
DEFINITION OF TERMS
Section 2. The term "private sewer" is applied to all sewers
that are not constructed by and under the provision of the City of
Centre]. Point. The term "house sewer" is applied to that part of the
main drain or sewer extending from a point FIVE feet from the outer
wall of the building, vault, or area to its connection with public
sewer, private sewer or septic tank.
The term "house drain" is applied to that part of the main
horizontal drain and Its branches inside of the walls of the bui din ;s,
vault or area extending to and connecting with the house sewer.
The term "soil pipe" is applied to any line or pipe receiving
the discharge of one or more water closets with or without other fix-
tures.
1.
The "vent pipe" is applied to any special pipe provided to
ventilate the system of piping and to prevent the trap siphonage and
back pressure.
The term "branch vents" is applied to the branches from the
fixture trap to the main vent. The term "unsanitary" is applied to the
followings
To any fixture whose trap does not maintain a proper seal.
To any fixture not having a proper or sefficient water
supply to thoroughly flush it out and keep it in a clean and whole-
some condition.
To any drain, soil or waste or vent pipe which is rot gas
tight or emits any foul or obnoxious odors.
To any drain, soil or waste or vent pipe that is stopped or
partially stopped up.
To any water closet apa.nlJnent which is not thoroughly venti-
lated or has the floor saturated with urine or containing a foul odor.
To any imperfect fixture, pipe or trap.
To any work not conforming with the rules of this ordinance.
To any things which are detrimental to health,
The term "drain_aVe work" is applied to the house sewer and
house drain and its horizontal branchs collectively or separately.
The term "plumbing work" is applied to all fixtures having
a waste outlet from them to any soil, waste or vent pipe.
CONNECTING SOIL AND WASTE PIPE
Section 3. In every building where there is an exterior or
interior water closet there must be at least one pipe of rot less than
four inches in diameter, extended through the roof. No closet vent
pipe shall be less than two inches in diameter. When nine or more
water closets are connected to one soil or drain pipe, said soil or
drain pipe shall not be less than six inches in diameter and shall
have not less than one six inch vent continued up to and through the
roof.
Waste pipes for water closets shall not be less than four
inches in diameter.
Waste pipes : Horizontal waste pipes for sinks shall be
cast of iron or lead or galvanized iron and shall not be smaller in
diameter than traps used. Horizontal waste pipes up to twenty feet
in length, shall be a minimum of one and one half inches in diameter
and all pipes in excess of twenty feet shall be a minimum of two
inches in diameter. Vertical waste pipes for sinks may be of galvaniz-
ed iron. Only recessed cast iron drainage fittings may be used on
these vertical lines of waste pipe. For bath tubs and lavatories,
galvanized pipes may be used, cast iron drainage fittings only to be
used on such waste lines.
HOUSE DRAINS
Every house or building hereafter connected to public sewer
or private septic tank shall have the house drain through which sewerage
2,
is carried constructed of cast iron pipe, which shall extend five feet
outside of the building or foundation line. The drain is to be laid in
trenches of uniform grade or suspended from floor timbers by strong
iron rangers; they shall have proper fall of not less than one»quarter
of an inch per foot towards the main sewer and in as straight a line as
possible. All changes in directions or connections to soil or waste
pipes shall be made by means of Y branches, one-eighth or one-isisteenth.
No angles shall be made jointing cast Iron pipes together, but shall be
made with required fittings or• bonds. Sanitary tees shall only be used
in vertical lines of pipe. Heel outlets shall not be used for vent
connections except on a vertical line of vent pipe. There shall be a
cleanout put in the house drain at the last change of direction or
some accessible part of the main horizontal line in the building.
All cleanouts shall be not less than the size of the horizontal line
and shall be closed by brass screw covers with not less than six threads
of iron pipe, standard thread and shall be kept accessible; when drains
are laid beneath the floor, cleanouts shall run to basement level from
Y branch. There shall be a cleanout installed as per the above specifi-
cations at the last bend outside of the structure except in case of
basement installation,
SEWERS
Section 4. In no case shall terra cotta or cement sewer
pipe be allowed under any building or shall any builder, lessee, tenant
or occupant of any building, nor any plumber or person or persons
interested in the plumbing work about such building, allow any terra
cotta or cement sewer pipe to be laid within FIVE (5) feet of such
building and in all cases before a new or old building is placed or
remodeled on any lot which has a terra cotta or concrete sewer system
must be replaced by an iron soil pipe which must be extended FIVE (5)
feet outside of the building or areas.
All sewers used for drainage in the City of Central Point
shall not be less than four inches in diameter where used for the disc»
charge from water closets.
All joints in terra cotta or cement pipe shall be made with
equal parts of the best Portland cement and clean, sharp sand; each
joint shall be carefully cleaned on the inside when it is laid; the
cement must be pressed into the hub and beveled outside the socket
and made smooth, and solid and left uncovered until examined by the
Inspector of plumbing, said examination to be made within sixteen
working hours after being notified. It shall be unlawful for any
person to connect any building with public sewer or provate cesspool,
or construct cesspools except under the direction of a bona fide master
plumber, or by obtaining a permit from the inspector of plumbing and
draira .e, to construct cesspools except such lateral sewers as may
be put in under the direction of the City Engineer of the City of
Central Point, and in no case shall such laterals extend inside the
property lines.
When sewer pipe under any building becomes defective it
must be replaced with cast iron pipe, no sewer pipe shall be connected
in to iron pipes on any premises,
STRENGTH OF SOIL PIPE
The cast iron soil pipe and fittings must be sound and
free from holes and cracks and of a grade known as standard. The
following weight per lineal foot will be accepted as complying with
the Ordinance.
3.
STANDARD:
2-inch . . . 3- pounds per lineal foot
3-inch 4* pounds per lineal foot
4-inch . . 6g pounds per lineal foot
5-inch . . . . . . . . . . 8 pounds per lineal foot
6-inch ,lO pounds per lineal foct
7-inch 1!1 pounds per lineal foot
8-Inch 18 pounds per lineal foot
The size, weight and maker' s name must be cast on each length of
pipe fittings.
LEAD TRAPS AND WASTE PIPES
Lead traps and branch waste pipes shall not be less than
the following sizes and must be drawn lead of the best quality and
not less than the following weight per lineal foot:
4 inches 5 pounds per foot
3 inches 4pounds per foot
2 inches 4 pounds per foot
l� inches 3 pounds per foot
14 inches , . 21pounds per foot
No trap screws shall be concealed on any premises. Traps
with partitions or any mechanism forming seal are prohibited.
JOINTS AND FERRULES
Joints in cast iron pipes shall be made with pure lead and
picked oakum, well caulked with no paint, varnish or putty allowed
in caulking said joints. Joints in wrought iron pipes shall be
screwed joints. Joints in brass or lead pipe shall be in all cases
wiped solder joint or screwed joints, with standard iron pipe thread.
Joints between lead and iron pipes shall be made by heavy brass caulk-
ing, ferrules or solder nipples, the full size of the pipes. Approved
combination ferrules may be used. Double hubs shall be used only in
vent pipes. Flange joints connecting lead pipes together or lead
and brass, where concealed are prohibited. All brass ferrules shall
not be less than four inches long.
SEPTIC TANI( AND CONNECTIONS
Section 5. In all cases where a nc-.v building is erected,
or where a house drainage end water closet accommodations are main-
tained within two hundred feet of a public water spply, all plumb-
ing shall be connected with city sewer where sewer is within two
hundred feet or septic tank of approved type and size. No parson
or persons shall withir the corporate limits of the City of Central
Point erect or maintain or suffer to be erected or maintained, upon
any premises owned by him, her, or them, any privy or septic tank
upon any lot or parcel of land abutting upon any street in which
there has been constructed and is being maintained a public sewer.
VENTILATION
Section 6. All waste pipes must be protected from siphonage
and waste pipe leading from them ventilated by a special air pipe.
Each and every trap shall be ventilated by an air pipe., kIn the cases
where the size of trap is two inches or less, the vent pipe shall start
not more than four inches away from the water line of traps, except P
traps, which shall not be more than 24 inches from water line in trap,
providing there is not more than one inch fall between the trap and.
vent pipe.
All vent branches must be taken from the top of the waste or
the crown of the trap, and all changes made in the direction_ of vent
pipes below the top of the fixture shall be made at an angle of not
less than 45 degrees. No horizontal vent pipes will be allowed
below the top of the fixture they serve. The branch tees of vent pipes
44.
/ 4
•
• � 1
shall not be less than one foot above the top of fixture. r?ot less than
fifteen inches of two inch lead shall be used on revents from closets or
lead. traps or bends larger than two inch in size. No unions shall be
used other than a ground join union, In cases where waste pipes are
roughed in for extra fixtures, said fixtures must also be vented or vent
pipe must run to some accessible point for connection when fixtures are
set. The highest small single fixture on vertical line of soil pipe
not less than four inches in diameter, and within two feet of the same,
need not be back vented, Small fixtures may be connected to lead bend
providing they connection above the center line of bend and are vented
to conform with Section 6.
On vent or air pipes from traps thirty-five feet or less in
height, not more than two small fixtures can be ventilated from a one
and. one quarter inch pipe or more than four, from a one and one-half
inch pipe, or more than eight from a two-inch. pipe. Not (See Section 3)
more than one water closet, including four small fixtures can be ventilated
from a two--inch pipe, or more than two water closets, and two small
fixtures. Not more than three water closets and eight small fixtures
can be vented from a two and one half inch pipe, or four elcsets and
four small fixtures can be vented from a three inch pipe or eight
closets and eight small fixtures on a four inch vent, Nine or more than
the previously described amount of fixtures may be ventilated by irse
creasing the vent pipes in proportion to accommodate the desired amount
of fixtures, When two fixtures are set back to back and traps serving same
are not over twelve inches from the vent, said. traps will not be re..
quired to be back vented, provided the main waste and vent are one size
larger than the traps used., excepting water closets which may be three
feet from the main four inch stack and the vent to extend full size
through the roof to the main vent.
Air pipes may be combined by branching together those which.
serve several traps, in which case the size of the main line must be
increased as it receives the several additions to the size above speci-
fied, and may be connected to soil pipe twelve inches above the highest
fixture, which. soil pipe must be of ample size. These air pipes and
fittings must have a continuous fall to drain all water formed by con-
densation. All vent pipes and fittings must be of cast or galvanized
iron or lead pipes. When old work is repaired, back vent pipes, if in
the partition running direct to waste pipe and in good condition and of
the size required, may remain. No brick, sheet metal, earthen or chimney
flue shall be used for sewer ventilating.
TERMINALS OF VENT PIPES
The terminals of all vent pipes must be at least one foot
above any air shaft or window or twelve feet avay from the same and two
feet from the terminus of any chimney and. not less than one foot above
the roof, Vent pipes when not twelve feet from window or other openings
must be combined, and where possible connected to the main vent stake
below the roof of the building. Vent pipes in no case shall extend. more
than three feet above the roof of any building, except outside water
closets, which set away from the building.
When one building is attached to or within twelve feet of
another building of greater height, having windows or openings over
looking the lower building, the terminals of all vent pipes of the
lower building must be at least twelve feet from said windows or
openings, or shall be carried up above the eaves or fire walls of the
higher building. There shall be no caps, cowles or return bends put
on the end of any vent pipe.
5.
ROOF FLASHING
Section 7. All pipes running through the roof of any
building shall be made perfectly water tight by means of flashings.
ROOM VENTILATING
Water closets and slop sinks must never be placed in an
unventilated room or compartment. In every case the compartment
must be opened to the outer air or be ventilated by means of a shaft
or air duct, at least one hundred square inches in area, and placed
as near the citing as possible and carried thence through the roof
or the outside wall,
FLOOR DRAINS
All floor drains when connected to sewer 'hall be trapped
with not less than a two inch trap and equipped with a bck water
valve.
FIXTURES AND HOW TRAPPED
Section 8. The waste pipe from all fixtures shall he
separately and independently trapped. The traps shall be placed as
near as practicable to the fixtures it serves. No fixtures shall be
set unless supplied with sufficient water to properly flush it.
Where not more than three wash basins in barber shops or
office buildings are combined in one place, one trap may be used at
the center basin, provided the said basins are not more than four
feet apart. The discharge from any fixture must not pass through
more than one trap before entering the main drain.
GREASE TRAPS
There shall be installed at all sinks when deemed necessary
by the City Superintendent, a grease trap of design and capacity
acceptable to the City Superintendent, to dispose of any grease placed
in said sink.
WATER CLOSETS
Section 9. All water closets installed must be of an
approved type and all other types already in use must be replaced
when found defective.
Enclosing of water closets with wooden casings shall not
be permitted.
In factories, workshops, and packing houses where there
are twenty persons or less employed there shall be provided one water
closet, but where there are persons of each sex employed there shall
be provided a separate water closet for each sex. An additional water
closet shall be provided for each additional twenty persons of either
sex or part thereof.
Every tenement or lodging house shall be provided with one
water closet for every ten rooms or iminmum thereof, and one sink for
each floor.
All residences shall be provided with at least one water
closet and one sink.
6.
WATER CLOSET FLANGES
All water closets shall be fastened to the floor with a
cast brass or cast iron flange, not less than one.-eigth of an inch
thick, and made perfectly tight with a putty connection.
URINALS
Section 10. All urinals shall be constructed of materials
impervious to moisture and that will not corrode ender the action of
urine, and no sheet other than copper or brass shall be used for
urinals. Urinals in all public buildings shall be automatically
flushed at least once each thirty minutes.
WOODEN OR WOOD LINED VESSELS
Section 11. No wooden sinks or wash trays shall be in-
stalled in any residence or tenement house which is used as a dwelling,
but may be used in photograph galleries and in kitchens in hotels and
restaurants. Wood lined sinks or wash trays or bath tubs shall not be
permitted.
REFRIGERATOR WASTE PIPES
Section 12. No waste pipe from a refrigerator or any other
receptacle where food is kept shall be connected direct to any sewer,
soil or waste pipe, and such pipe shall be not less than one inch. in
diameter and arranged for flushing.
STEAM EXHAUST
Section. 13. Any steam. exhaust, blowoff or drop pipe shall
rot be connected directly with the sewer, house drain, soil or waste
pipe nor with any rain water conductor. Steam shall be discharged
into a blow off or condensing tank and the waste or overflow from
said tank shall be provided with a suitable outlet to the main drain.
WATER PIPES
Section 14. Every service pipe must be provided with a stop
and waste cock in addition to the service cock placed by the city,
located at some accessible place, beyond damage from frost and so
situated that the water can be conveniently shut off and drained from.
the pipes. All pipes of the building must be so arranged as to drain
towards the stop and waste cock, or to the fixtures. All water pipes
and fittings shall be either galvanized iron, lead, brass or copper.
All joints shall be wiped on lead connections.
The foregoing requirements are in support of the laws and
regulations of the Oregon State ?hoard of Health, Plumbing Division,
and under no circumstances are to be considered. as superseding said
laws, which are considered to be the minimum requirements.
SPECIAL PERMITS
Section 15. When special fixtures or traps are required by
owners or architects for which. there is no provision in this ordinan ce,
or where conditions arise that demand the discretion of the inspector
of plumbing, upon examination, the inspector may give in writing to
7.
•
the owner or architect a permit, if in his judgmert, the conditions
demand the use of fixtures or traps, providing anti-.syphon traps are
used as approved by the inspector of plumbing.
TESTS AND INSPECTIONS
Section 16. When the plumbing work is sufficiently advanced
in any building for inspection and the plumber shall notify the inspector
of plumbing and drainage that work is ready for inspection, he shall
within sixteen working hours after such notification, inspect the
work and if found free from leakage and, the work done as prescribed by
the city ordinance, sign his name in full in space provided on the
plumbing permit and accept or reject the work under consideration.
In case the work is rejected the necessary changes or additions must be
made and the inspector notified for inspection as in the previous per-
formance. No work shall be considered ready for inspection until all
pipes are securely strapped in place, with iron hangers. No water shall
be turned into any building or buildings until the said building or
buildings are connected with the public sewer or private septic tank,
and the water permit signed by the inspector of plumbing.
POWER OF THE PLUMBING INSPECT3R
Section 17. The inspector of plumbing and drainage shall have
the power in all cases where there is a building being erected or re-
modeled to enter and examine all work pertaining to plumbing at any
time, and shall have the power to stop any or all work not complying
with the requirements of this ordinance and where there is a public
sewer in any street or alley, to cause any owner of land upon or adjoin»
ing such street or alley, his agent or tenant, to make sufficient drain l
and proper sewer connections for his or her house, yard. or lot, closet
or premises, whenever, ir his opinion the same be necessary. He shall
have the power to examine all buildings, during reasonable hours, as to
the plumbing, drainage and ventilation thereof, and when, in his
judgment the plumbing fixtures are found to be defective or unsanitary,
he shall have the power to order their removal or repair or substitution
of other fixtures and to require the ventilation and drainage of such
buildings to be placed in a sanitary condition and he shall thereupon
give the owner, agent or tenant, or person occupying the buildings, or
premises, notice in writing, specifying the time when any defective
drain, sewer connection or unsanitary plumbing fixtures must be com-
pleted. He shall keep a copy of such notice in a book which shall be
kept in his office, and open to inspection by the public during his
office hours. Tf said agent, owner or tenant neglects to carry out
said order within the time speci fed he or they shall be liable to a
fine of not less than ten dollars, not more than one hundred dollars,
and any owner, agent or tenant shall be jointly and severally liable
therefor.
PLUMBING INSPECTOR AND BOARD OF
EXAMINERS
Section 13. The plumbing inspector and his deputies shall
be appointed by the mayor, and no person who shall be engaged in or
having any pecuniary interest in any plumbing business or any plumbers
supply business, shall be appointed to or retain the position of inspec-
tor of plumbing or deputy, thereto.
The board of examiners shall consist of the inspector of
plumbing and drainage, one master plumber, and one journeyman plumber
8.
all appointed by the v_ay or of the City of Central Point. They shall
examine all applicants to ascertain their qualifications theoretically
and practically to construct and to supervise plumbing wor':c, and shall
issue a certificate to each applicant passing a satisfactory examina-
tion who thereafter shall be known as a master plumber. In case an
applicant fails to pass the required examination he shall not be eli-
gible for a second examination within six months thereafter. The ex-,
sriining board shall meet on the second Monday of the month to arrange
for examination and to transact other business and shall have full
power to act on all applications.
PLANS AND SPECIFICATIONS
Section 19. Copies of plans and specifications of all pro-
nosed plumbing installations must accompany the application for a
plumbing permit when deemed necessary by the plumbing inspector, If
such plans and specifications comply with all of the provisions of
this ordinance, the plumbing inspector is authorized, to issue a per-
mit,.
Nothing in this section shall be construed as requiring
bond, examination, or license from any person for doing his own work
or emergency work, provided the work otherwise complies with the rules
and regulations,
LICENSE
Section 20, Each person or firm conducting a plumbing busi-
ness within the jurisdiction of this ordinance shall have a license and
shall ,pay a license fee of $100.00 for the first year, payment whereof
may be arranged by the plumbing inspector in such amounts, and on such
conditions as in his discretion fit the circumstances of each particu-
lar case. This fee shall be for one full year and at the end of that
time the licensee shall be required to pay a pro rata fee on a k25,00
a year basis frenn that time to the first day of January of the next
year. A license fee of $25.00 shall be paid for each succeeding year,
payable in advance on the first day of January of each year,
No license shall be iseged to any person or firm to conduct
a plumbing business until they have been registered as plumbers with
the inspector of plumbing and drainage,
DUTIES OF INSPECTOR
Section 21, The inspector of plumbing (or his deputy)
shall perform the duties as hereinbefore outlined and shall, upon
being notified, examine all plumbing and drainage inside of property
lines before the same are covered, If upon examination he shall find
requirement of this ordinance are violated he shall report same to
contracting plumbers and demand an immediate correction,
The inspector of pleirribing shall turn over all moneys he may
collect to the City Treasurer and take his receipt therefor.
PENALTIES
Section 22. Any person, firm or corporation violating any
of the provisions of this ordinance shall be deemee guilty of a mis-
deameanor and each such person shall be deemed guilty of a separate
9.
. " - • ' • •
offense for each and every day or portion thereof during which any
violation of any of the provisions of this ordinance is committed,
continued or permitted and upon the conviction of any such violation
such person shall be punishable by a fine of not more than $100*00
or by imprisonment in the City Jail for not more than 50 days or
by both such fine and imprisonment.
there -and.__sal___ordindhces in conflict he ,
Section 24. It is hereby adjudged and declared that ex-
isting conditions are such that this ordinance is necessary for the
immediate preservation of the public peace, health and safety, and
on account thereof an emergency is hereby declared to exist, and
this ordinance shall take effect and shall be in full force and effect
from and after its passage,
passed by the City Council and signed by me in open
session in authentication of its passage this of , 1951.
Mayor
Approved by me this day of , 1951.
S
Mayor
Attest:
Cr-teee
Recorder