HomeMy WebLinkAboutOrdinances 289 • •• ORDINANCE NO. • 289 THE BUILDING CODE of THE CITY OF CENTRAL POINT OREGON , , • • ORDINANCE NO. 289 - AN ORDINANCE REGULATING THE CONSTRUCTION, ALTERATION, REPAIR AND MOVING OF BUILDINGS WITHIN THE CITY OF CENTRAL POINT PROVIDING FOR PERMITS AND FEES THEREFOR; PROVIDING FOR PENALTIES FOR VIO- LA TION THEREOF; AND PROVIDING FOR THE REPEAL OF ALL ORDINANCES OR PARTS OF ORDINANCES IN CONFLICT HEREWITH. THE PEOPLE OF THE CITY OF CENTRAL POINT DO ORDAIN AS FOLLOWS : PART I ADMINISTRATION Section 1: This Ordinance shall be known and cited as"The Building Code of The City of Central Point, Oregon'. Section 2: The purpose of this code is to establish and enforce minimum standards of safe design and construction forall structures hereafter erected, altered, repaired, or removed within the limits of the City and to promote the public health, welfare and safety. This code shall invoke the police power specifically or impliedly delegated to the City, and shall be liberally construed to effect its purpose. The requirements of this code shall be deemed to supplement the laws of the state and all ordinances, rules , and regulations pertaining to use, occupancy, fire hazard, safety and sanitation. / Section 3 : No structure or part of a structure shall hereafter be built, altered, repaired or moved until a building permit there- for has been granted by the building official. All structures hereafter built, repaired, altered, or moved are subject to inspec- tion by the building official. The building official shall have the right of entry at any convenient time for the purpose of en- forcing the regulations contained in this code. Section 4: The construction details are included in this code as part VII. Section 5: The office of building official is hereby created. The building official shall be appointed by the Mayor with the con- sent of a majority of the council. he is hereby charged with the administration and enforcement of this code. Section 6: Application for a building permit shall be filed by the owner or his agent with the building official upon a form pro- vided for the purpose and giving such information as the building official shall require. Such application shall be accompanied by two complete sets of plans and specifications including plot plans showing the relationship of the proposed building to abutting property lines and buildings. if, in the opinion of the building official, the c h-a ratter of the work is sufficiently described in the application, he may waive the filing of plans provided the cost of such work does not exceed one thousand dollars (4$1,000) . Section 7 : If the building official finds that the proposed building will comply in every respedt with this code and the laws of the state of Oregon, he shall issue a building permit therefor, and shall write "approved" on one set of the plans and specifica- tions , which shall be kept at the site of the proposed building. After issuance of the building permit, the plans and specifications shall not be altered unless such change is approved by the build- ing official as conforming to this code. (1) 1 Section 8: The building official shall order a stoppage of work on any type of construction for which a permit is required at any time that he finds the provisions of this code, or plans and speci- fications approved under this code, are not being complied with. He shall post a copy of this order at the site of construction and N serve a copy thereof upon the permittee or his agent. Upon receipt of this order the permittee or his agent shall forthwith cease work. The building official shall not lift such order until supplied with satisfactory evidence that the violation is corrected. The building official shall serve notice upon the permittee or his agent that the stop work order has been lifted before work may be resumed. Stop work orders shall be in addition to other penalties provided for violations of this code. Section 9 : A building permit shall become void unless operations are commenced within six months from date thereof unless such time is extended by the building official. Section 10: The building official shall be notified by the holder of the permit, and the building official shall inspect the build- ing, 1. When the foundations are ready to be placed. 2. When the foundation is completed and before sub-floor is laid. 3. When the structural frame is complete. 4. when the building is completed. Section 11. A building board of appeals is hereby created. It shall consist of three members who are qualified by experience and training to pass on matters pertaining to building construction. It shall be appointed by the mayor with the consent of a majority of the Council, and shall hold office at the pleasure of the Mayor. The building official shall act as secretary of the board of appeals , and shall keep a record of its decisions. Section 12 : Any person who feels that an injustice has been done him by any order ox4 ruling of the building official may appeal there- from to the board of appeals by filing a written notice of his appeal with the building official within ten days after receipt of the order or ruling complained of. the decisions of said board shall be limi- ted to the interpretation of the provisions of this code. It shall adopt rules of proceedure for matters coming before it and its dec- isions shall be governed by a majority vote. It shall render its findings and decisions in writing, one copy thereof to be filed with the building official and one copy to be delivered to the appellant. The decisions of the board shall be conclusive except in case of mistake or fraud. The board may recommend to the city Council any amendments to this code or new legislation that it may deem advis- able. Section lai Before receiving a building permit for a group I or 11/ group II building as hereinafter defined, the owner or his agent shall pay the City Recorder the following fees : No fee for work the value of which is less than fifty dollars. One (S1.00) dollar for work the value of which is more than fifty ( 50) dollars but less than five hundred ( 500) dollars. Two (2) dollars for work the valuation of which is more than five hundred ( 500) dollars but less than one thousand (1,000) dollars. Two (2) dollars for each additional one thousand (1,000) dollars or fraction thereof of total valuation up to fifteen thou- sand (15,000) dollars. (2) • One (1) dollar for each additional one thousand (1,000) dollars or fraction thereof of total valuation over fifteen thousand (15,000) dollars i/Ten (10) dollars for moving a building. The City, county, state, or the United States shall be exempt from paying fees for a building permit. Section 1 -: New materials , systems of construction, and devices may be approved by the building official when they are determined to be equal to those required in this code. The building official shall be guided in such approval by the results of tests conducted by the testing laboratories of the National Bureau of Standards , The Underwriters Laboratories , Inc. , or by any other testing agency or committee whose standards conform with the above agencies. Section 15: Any alteration to the structural portion of any build- ing or any alteration necessitated by a change in type of occupancy resulting in an increased floor load shall conform to the require- ments of this code. All buildings and structures now existing or hereafter erected shall be maintained in a safe condition. L, Section 16: Every application for a permit to move a building shall designate the site of the building to be moved and the site to which the building is to be moved. Permission to use the pubic streets shall be obtained from the proper authority. c, Section 12i Any person, firm, or corporation who violates or refuses to comply with any provision of this code shall be deemed guilty of a misdemeanor and shall be punished by a fine of not more than. One hundred (100) dollars , or by imprisonment, of not more than thirty (30) days , or by both such fine and imprisonment for each provision violated. It shall be the responsibility of the offender to abate the violation and each day that such violation is permitted to exist shall constitute a separate offense. Section 18 : Should any section or provision of this code be dec- lared by a court of competent jurisdiction to be invalid, such decision shall not affect the validity of the code as a whole or any part thereof other than the part so declared to be invalid. Section 121 All Ordinances or parts of Ordinances in conflict with the provisions of this code are hereby repealed. PART II DEFINITIONS Section 20: In the interpretation of this code, the following definitions shall be used; Alteration means any change or addition in constructuin or arr- angement or any change in type of occupancy. Building means any structur constructed for the shelter of persons, animals, or property of any kind. Court means an unoccupied space extending to the sky from the ground or from the roof of a lower portion of a building, such space being adjacient to the building and enclosed on two or more sides by walls of the building. Dwelling means a building or that part of a building arranged or occupied as the home or sleeping place of one or more persons. (3) • • • Gara. e means a building which affords shelthr to a motor vehicle uding a volatile flammable liquid as a fuel. Grade of a building means the established or finished ground ele- vation. this is used in determining the number of stories and height of the building. If a building wall is built up to or within five feet of a street lot line, the grade is determined by the sidewalk elevation at the center of the length of the wall fronting on such sidewalk. If the building has two or more such walls, the grade shall be the aversge of the sidewalk elevations at such points. If the building walls are more than five feet from the street lot line, the grade shall be the average of the finnished ground ele- vations at each wall of the building, measuring each elevation of the ground at the center point of the length of the wall. Habitable room means a room occupied or arranged for living, eat- ing, or sleeping purposes , including kitchens for family units or individual households, but not including bath or toilet rooms , laundries , pantries, corridors, or recreation rooms. Height of building means the vertical distance from the grade of the building to the highest point in the coping of a flat roof or to the deck line of a mansard roof or to a point halfway between the eaves and the highest ridge of a roof. Loads. Live loads mean the load carried by a building or structure not including the weight of any part of the building orstructure and not including any loads caused by wind, earthquake, and later- ally exerted pressure of earth or other materials, liquids or gasses. Bead loads mean the actual weight of roof, walls , floors , partitions, and other permanent parts of building. Masonry means units of brick, stone, concrete, tile or terracotts laid in mortar and includes monolithic concrete. Repairs means the reconstruction or renewal of any part of a build- ing or structure for the purpose of its maintenance. The word "repair" does not apply to any change of construction. See alter- ation. Story means that part of a building between the upper surface of a floor and the upper surface of the floor next above except the top story which is that part included between the upper surface of the top floor and the ceiling or if there is no ceiling, the underside of the roof. Wall means the vertical structural members of a building which en- close it, form its courts , or form its vertical fire divisions. Wall, bearin . Bearing wall means a wall which carries dead loads other than its own weight. Wall, fire, means a wall of four-hour fire-resistive construction which divides a building or separates buildings for the purpose of restricting the spread of fire and which starts at the foundation and extends continuously through all stories to and above the roof. But where the roof is fire-proof or semi-fireproof the wall shall be carried up tightly against the underside of the slab. Wall, non-bearing. ITon-bearing wall means a wall which supports no load other than its own weight. Wall, party. Party wall means a wall which separates two or more buildings or is built to be used jointly by separate buildings. (4) PART III CLASSIFICATION Section 21: For the purpose of this code all structures shall be classified in one of two groups : Group I. Those structures whose construction is completely covered by this code : (A) Buildings used as single or two-family dwellings constructed of frame construction not exceeding two stories in height with or without an attic, or of ordinary masonry construc- tion not exceeding one story in height with or without an attic. (B) Buildings used for stores , offices , shops , or warehouses not exceeding one story or 25 feet in height. Dry-cleaning establishments, garages accomodating over four (4) cars , and places of assembly or detention shall be reg- ulated as group II buildings. (C) Private Garages not exceeding one story in height of frame or ordinary masonry construction with a capacity of not more than four (4) cars, wood sheds , chicken houses, and other similar buildings accessory to those allowed in parts (A) and (B) of this section. Buildings designated in parts (A) , (B) and (C) of this section involving a ground area in excess of 4,000 square feet or the use of structural reinforced concrete, structural steel, heavy mill construction, or roof trusses , shall be regulated as group II buildings , except that the incidental use of steel beams, columns, lintels , and hangars and of reinforced concrete slabs shall be permitted in group I buildings. Group II. All structures not included in group I shall be classi- fied as group II. Section 22 : All Group II buildings , unless otherwise provided in this code, shall conform to all of the provisions , except Part I (Administrative) and Part IV ( Requirements Based on Location in Fire Zones) , of the 1949 Edition of the Uniform Building Code, prepared by the Pacific Coast Building Officials Conference, which is hereby made a part of this code and adopted by reference. One copy of said code shall be placed on file in the office of the building official for public use and inspection and shall be mar- ked "Official Coil" . ,A11 Group II buildings shall be designed by, and their construction V shall be supervised by an architect or engineer registered in the State of Oregon. Upon completion of a structure, such architect or engineer shall be required to make and file with the building official an affidavit stating under oath that the provisions of this code have been complied with. ( 5) PART IV STANDARDS OF DESIGN AND CONSTRUCTION Section 23 : The minimum live loads per square foot for floors and roofs shall be as follows : (a) Floors (Minimum live loads in lbs. per square foot) Private dwellings , dormatories , hotels , guest rooms , apart- ments, and hospital rooms 40 Offices and assembly rooms with fixed seats 50 Public rooms,corridors , balconies , and public stairways. . 100 All floors other than the above shall be designed for actual loads, but in no case less than 100 (b) Roof load per square foot of horizontal projection 30 Section 24: All measurements of dimension lumber given in this code are nominal unless otherwise noted. (a) The minimum thickness of floor or roof beams , joists, or rafters shall be 2 inches. (b) The ends of joists , beams rafters , and girders entering masonry walls shall be beveled 3 Inches in 12 inches from the vertical, with 1 inch air space on each side and on the top. Such members shall be tied to the wall with a metal anchor once in every 8 lineal feet of wall and shall have not less than 32 inches of bearing. (c) In frame construction, sills shall be anchored to the foundation walls at 6 foot intervals or less by bolts not less than inch in diameter embedded at least 6 inches in the foundation walls. (d) the Maximum spacing of floor joists shall be 16 inches center to center. (e) Maximum allowable spans for joists and rafters, as designated in the table, are based on fiber stress of 1200 lbs. per square inch and on the following maximum allowable live loads : Floor joists 40 lbs. per square foot Ceiling joists , , . . none Roof rafters 30 lbs. per square foot if flooring is to be installed over ceiling joists, they shall have the same allowable spans as floor joists. (6) r.. • ! - Size Spacing Floor joists Floor joists Ceiling Rafter plastered unplastered joists span below below 2"x4" 12" 11'-0" 8'-10" 16" 10'-0" 7t- 8" 24" 8'-1_t" 6 '- 4" 2"x6" 12" 10'-8" 12 '- 0" 161- 7" 13g- 6" 16" 9 '-6" 10'- 0" 15'- 4" 11 '-10" 24" 13 '- 8" 9 '- 9" 2"x8" 12" 14'- 1" 15'-11" 21'- 8" 17'-10" 16" 12 ' 11" 13 '-11" 20'- 2" 15'- 7" 24" 181- 0" 12 '-11" 2"x10" 12" 17'- 9" 19t-11" 26 '-10" 22'- 4" 16" 15'-10" 17 '- 4" 25t- 0"" 19 '- 7" 24" 22'- 6" 16I- 3." 2"x12" 12" 21'- 4" 23 '-11" 16" 10 '- 1" 20'-11" 2"x14" 12" 24'-11" 27'- 8" 16" 22 '- 4" 2+' - 4" 3"x6" 12" 12 ' - 4" 15'- 0" 16" 11 '- 3" 131: 1" 3"x8" 12" 16 '- t+" 19 '- 8" 16" 14'-11" 19 '- 4" 3"x10" 12" 20'- 6" 24 '- 7" p~ 16" 18 '-10" 21'- 8" 3"x12" 12" 2 1-'- 6" 29t- 4" 16" 22 '- 7" 25'-11" 3"x14" 12" 2.8 '- 7" 30'- 6" 16" 26 '- 4" 30'- 3" Note: A fiber stress of 1200 lbs. per square inch applies to Douglas Fir and Southern Pine of a structural grade. For woods having a fiber stress of 1000 lbs. per square inch to 1200 lbs. per square inch, reduce the span 1/6th. No wood having a fiber stress less than 1000 lbs. per square inch shall be used as a structural member. Joists supp- orting loads greater than 40 lbs. per square foot shall be designed in accordance with standard practice. (f) Joists or rafters not resting on masonry shall be supported on bearing partitions or by beams, girders, hangers , or trusses. (g) Joists and rafters may be notched at the support but such notch shall not exceed 1/5th the total depth of the joist or rafter. (h) Where live loads do not exceed 50 lbs. per square foot, a wooden strip at least 2" by 4" , strongly spiked or bolted to the girder, may be used to support joists or rafters. (i) Header joists over 6 feet long and tail joists over 12 feet long shall be hung in joist or beam hangers or secured by other devices affording equivalent support. Trimner and header joists more than 4 feet long shall be doubled. ( j) All floor joists shall be bridger once in every 8 feet of span. Each member of wood cross bridging shall be not less than 1 inch by 4 inches. (k) Girders supporting wood joists carrying a 40 lb. per square foot live load shall be not less than 4" by 4" (actual dim- ensions) for spans up to 5 feet and not less than 4" by 6" ( (actual dimensions) set on edge, for spans fron 5 feet to 7 feet. Girders for longer spans or greater loads shall be designated according to approved practice. (1) All wood shingles shall be nailed firmly with copper, zinc, zinc coated, or commercially pure iron nails of at least 14B and S guage and shall be not less than 1-_ inches in length. (7) . • Each shingle shall be nailed with not less than 2 nails driven substantially into the supporting roof construction. Maximum exposed length of wood shingles : 16" shingle 5" ( 5" to the weather) 18" shingle 52' ( 5i" to the weather) 24" shingle 7z' (72" to the weather) (m) All wood joist used to frame over unexcavated areas shall have a clearance of not less than 18 inches above the sur- face of the ground. Section 25: (a) The minimum size of an exterior wall or bearing partition stud shall be two inches by four inches . (b) The maximum spacing between centers os studs shall be 24 inches. (c) Flat studs shall not be used in exterior or bearing walls except where such walls are constructed double to receive a sliding door. (d) The exterior stud walls of all wood frame buildings of more than one story in height shall be diagonally braced at the corners by notching into the studs a 1 inch by 4 inch brace at an angle of 45 degrees except that it shall be optional to omit these braces if the studs are covered with boards apnlied diagonally. ( e) All partitions shall be framed solid at the corners so that no lath may extend from one room to the other. (f) Frame buildings may be veneered with masonry but such veneer shall be not less than 4 inches thick and shall be anchored to the wood frame or backing at intervals not exceeding 18 inches vertically and 16 inches horizontally by standard galvanized wall ties. The height of such veneer construction shall in no case be more than 20 feet above the grade of the building, and shall be carricd, on the foundation wall. Section 26 : Fire stopping shall be provided to cut off all con- cealed draft openings both vertical and horizontal, and to form an effective barrier between stories and between the top story and the roof space. It shall be used in specific locations as follows : (a) In exterior or interior stud walls at ceiling and floor levels. (b) In all stud walls and partitions , including furred spaces , so placed that the maximum dimension of any concealed span is not over lo feet. (c) In furred masonry walls . (d) Between stair stringers at least once in the middle portion of each run, at the top and bottom and between studs, along and in line with run of stairs adjoining such partition. ( e) Around top and bottom, aides and ends of sliding door pokets. (f) Spaces between chimneys and wood framing shall be solidly filled with mortar, loose cinder, or other incombustible material which shall rest on incombustible supports. (g) Any other location not specifically mentioned above, such as holes for pipes, shafting, etc. , which could afford a passage for flames. (h) Clothes chutes, wood hoists , and similar devices shall be equipped with self closing doors at all access points. (8) • • Fire stops, when of wood, shall be 2 inches thick. If width of opening is such that more than one piece of wood is necessary, there shall be two thicknesses of 1 inch material with joists broken. Floor joists in all types of construction shall be fire stopped at the end, and over supports for the full depth of the joists. No fire stopping shall be covered or concealed until inspected by the building official. Section 27: (a) Flue linings shall be manufactured from fire clay or other suitable refractory clgys and shall have a softening point not lower than 1994° Fahrenheit. Flue linings shall have a minimum thickness of 5/8 inches and shall be carefully bedded upoi one another in mortar with all joints left smooth on the inside. Masonry shall be laid up with mortar around each successive length of lining as it is set. all joints and spaces between masonry and lining shall be completely filled as each course of masonry is laid. No defective linings shall be used. Linings shall start 8 inches below the smoke pime intake or in the case of a fireplace from the apex of the smoke chamber and shall be continuous to the top of the chimney. no smokepipe intake shall be cut into a flue lining which is already set in place. (b) Mortar is defined as follows : Ratio by volume Cement Lime Sand Cement lime mortar. . . . 1 1 6 Portland Cement Mortar 1 4 3 Mortar used between joints of flue linings and in portions of the chimney above the roof or otherwise exposed to the weather shall be Portland Cement Mortar. Firebricks used for the lining of flues or facing of fireplaces shall be laid in fire clay mortar. Other parts of the chimney shall be laid up in cement lime mortar. (c) The walls of brick chimneys shall be built of solid brick and shall be not less than 3 3/4 inches thick and shall be lined, except that such lining may be optional. in residences if the walls are increased to 6 inches in thickness. (d) All brick shall be laid with full, push filled cross and bed mortar joints and shall be struck smooth where exposed to the weather. ( e) Concrthte chimneys cast in place shall be suitably reinforced vertically and horizontally. The walls shall be not less than 3-3/4 inches thick and shall be lined, except that such lining may be optional in residences if the walls are increased to 6 inches in thickness. (f) All stone chimneys shall be lined. Minimum thickness for walls of a dressed stone chimney shall be 8 inches. Minimum thickness for walls of other stone chimneys shall be 12 inches. (g) Masonry and concrete walls of buildings may form part of a chimney when the chimney walls are securely bonded into the walls of the building and when the flue is lined the same as in independent chimneys. Flues in party walls shall not extend beyond the center of the wall. (h) Hollow tile or hollow concrete blocks shall not be used for the walls of an independent chimney, but may be used for chimneys built as a part of an exterior wall of hollow masonry, in which case the chimney walls shall be at least 8 inches thick, and shall be lined. (9) ( i) Chimneys shall be built at least 3 feet above a flat roof and at least 2 feet higher than the highest elevation of any portion of the building within 10 feet of the chimney. ( j) Chimneys shall be built from the ground up and shall rest on concrete or solid masonry foundations. The footing of an exterior chimney shall start below the frost line and shall rest on undisturbed soil. Such footings shall be at least 8 inches thick and extend at least 6 inches beyond the face of the chimney wall. (k) Corbeled chimneys shall be supported by solid masonry walls at least 12 inches thick and the corbeling shall not project more than 1 inch per course and not more than 6 inches in any case. (1) No flue shall be built at an angle greater than 30° with the vertical. (m) Not more than 2 lined flues shall be permitted in the same flue space and the joints of any such adjoining flue linings shall be staggered at least 7 inches. (n) Fireplace walls shall be not less than 8 inches thick, and if built of stone, not less than 12 inches thick. The faces of all such minimum thickness walls exposed to fire shall be lined with firebrick, soapstone, cast iron, or other fire-resistive material. When lined with 4 inches of firebrick, such lining may be included in the minimum thickness. All Fireplaces shall have trimmer arches , reinforced concrete cantilever slabs , or other approved fire-resistive construc- tion supporting the hearth, and the hearth shall estend not less than 20 inches from the face of the chimney wall and shall be not less than 8 inches wider than the fireplace opening on either side. The flue area of a fireplace shall be not less than 1/12th of the area of the fireplace opening. ( o) Minimum flue sizes: Rectangular Rectangular Circular Lined flue unlined flue flue Small stoves and heaters 8"x 8" 8"x 8" 6"dia. Stoves, ranges, and heater 8"xl2" 12"x12" 8"dia. rooms Warm air furnaces, steam 12"x12" 12"x12" 10"dia. and hot waste boilers (p) Smokepipes shall enter the side of a chimney through a fire clay or metal thimble or flue-ring of masonry. The top of the smokepipe shall be at least 18 inches below the ceiling or joists . No woodwork shall be placed within 6 inches of a thimble. No intake pipe or thimble shall extend into the flue. (q) No wooden beams, joists , or rafters, or studs shall be placed within 2 inches of chimney walls and no woodwork shall be placed within 4 inches of the back of any fireplace. All ppaces between chimneys and members of the wood frame shall be filled with incombustible material supported by strips of sheet metal or metal lath set in the brick work and nailed to the wooden members. (r) Gas appliances using more than 5000 B.T.U. per hour shall be connected to an effective flue or outlet pipe opening to the outer air. Such flue shall be either a lined chimney or an outlet pipe of incombustible, noncorrodible material with bell and spigot or other acceptable joints. Such pipes, when located inside frame walls, shall have 1 inch clearance from all wood construction and shall be encased in an incombustible jacket. ( s) The use of porcelain enamel or other types of flues , which are approved by the Underwriters Laboratories Incorporated, shall be permitted under this code. (10) Section 28 : -7 The minimum thickness of exterior walls and bearing walls of masonry shall be as follows : 1. Cavity wall masonry 10" 2. Stone masonry (Ashlar) 12" 3. Stone masonry (Rubble) 16" 4. Other I Masonry walls when used in 1 story single-family dwellings and one story private garages not over 9 feet in height, provided that when gable construction is used an additional 6 feet is permitted to the peak of the gable 6" 5. Other masonry walls under conditions other than those specified in section 4 8" (b) The minimum thickness of interior non-bearing partitions of masonry shall be 4 inches. (c) In plain masonry of brick, all stretcher courses shall be bonded by making vertical joints over the centers of stretchers . Every sixth course shall be a header course and in no case shall there be less than one header in every 72 square inches of wall surface. If the thickness of the wall is greater than the length of one header, each header shall be covered by another header that breaks joints with the header below. (d) In plain masonry of stone, the bond stones shall be uniformly distributed throughout the wall and shall comprise not less than 20 per cent of the wall surface. There shall be atleast one bond stone for every five stretchers and each bond stone shall extend through the wall. Section 29: (a) Footings and foundations shall be constructed of solid masonry or of reinforced concrete and shall extend 6 inches below the frost line measured from the finished grade and to undisturbed soil, except that reinforced concrete footings and foundations may rest on fill when installed according to recognized good practice. (b) In no case shall the thickness of a foundation wall be less than the wall above, except that a masonry veneer wall may project not more than 3/4 inches beyond the outside face of the support- ing wall. No brick masonry, coursed stone, or concrete found- ation walls shall be less than 8 inches thick except that in. a 1 story frame dwelling or frame business building where the basement does not have a distance below ground exceeding 5 feet, a concrete foundation wall shall not be less than 6 inches thick. Any masonry in foundations or in walls in contact with the earth shall be laid with Portland cement mortar. Foundation walls supporting wood or light steel structural mem- bers shall extend at least 6 inches above the finished ground level. (c) Footings shall be acceptable without computation of the unit pressure under them if they have a minimum projection of four inches from all faces of the wall, column or pedestal, and if their depth is at least equal to their projection and never less than 6 inches. (d) Concrete floor slabs installed on the ground and driveway slabs shall be not less than 4 inches thick. (11) • • ( e) The space beneath a building not having a basement shall be enclosed by a concrete or masonry wall which shall extend from at least 6 inches above the finished grade to 6 inches below the frost line measured from the finished grade and to undisturbed soil. Such space shall be ventilated by at least two screened openings arranged so that air can circulate. The area of such openings shall be not less than 2 square feet for each 25 lineal feet or fraction thereof of exterior wall. PART V FIRE AND SAFETY Section 30: There is hereby established a fire zone which shall embrace that portion of THE CITY OF CENTRAL POSIT described as follows : Beginning at the center of the intersection of Pine and Fifth Streets and running thence Southeasterly along the center line of Fifth Street to the center line of Oak Street; thence Southwesterly along the center line of Oak Street to the Center line of South First Street; thence Southeasterly along the center line of First Street to its intersection with the South City Limits line; thence West along the City Limits line to the Westerly line of the South- ern Pacific Company property; thence Northwesterly along the Southern Pacific Company property line to its intersection with the West City Limits line; thence North to the Easterly line of the Southern Pacific Company property; thence South easterly along the Southern Pacific Company property line to the north City Limits line; thence East to the Center of North First Street, extended; thence Southeasterly along the center line of First Street to the center of TManzanita Street; thence Northeasterly to the center of Fifth Street; thence Southeasterly to the point of beginning. Section 31: Any existing building within the fire zone which be- / comes damaged to an extent of 50 per cent of the replacement value be- t/ of the date of the damage, by fire, decay, or otherwise, shall not be rebuilt unless the entire building when so rebuilt will conform to this code. When damage thereto is less than 50 per cent of the replacement value thereofas of the date of the damage, the structure shall not be rebuilt to a elevation higher than the highest part left standing after such damage shall have occurred, or so as to be in better state of repair or to occupy a greater space than before it was damaged. The extent of the damage that has been done to any such building by fire, decay, or otherwise, shall be deter- mined by three disinterested persons, residents of The City of Central Point, one of whom shall be selected by the owner or agent of the building, the second by the City Council or authorized official, and the two so chosen to select the third. The persons so chosen shall fairly and impartially estimate the damage, and their decision shall be final and binding upon all persons concerned. (12) • Whenever any building shall be found to be damaged to an extent of 50 per cent of the replacement value thereof, by fire, decay or otherwise, notice of such finding shall be served in writing by the City Council or an authorized official, on the owner or agent of said building, and thereaftersaid building shall be and the same is hereby declared, a public nuisance and shall be abated. Failure of the owner or agent of said building to remove the same within thirty (30) days after receipt of written} notice of the finding hereinabove referred to, shall be fined in the sum of not exceeding one hundred (100) dollars. Each day the same shall be permitted to stand after the receipt of such notice in writing and the expiration of said 30-day period, shall constitute a separate offense. In case the owner after due notice fails to remove or abate the structure within sixty (60) days after service of notice, ?he City shall remove and abate said nuisance. The Council shall ascertain and declare the cost of said work, and assess the same against the property upon which said building is located. Said assessment shall be declared by resolution, and it shall be entered in the docket of City liens, and shall there- upon be and become a lien against said property, and the creation of said lien and the collection and enforcement of said cost shall be done in substantially the same manner as in the case of cost of street improvements, but irregularities of informalities in the proceedure shall be disregarded. Section 2 : Buildings hereafter erected, constructed, or moved into the fire zone shall conform to the following minimum requir- ments : (a) Four-hour fire-restive construction - Fire walls and party , walls. (b) Two-hour fire-resistive construction - Exterior walls. (c) One-hour fire-resistive construction - Floors; roofs , stairs , , shafts , inner bearing walls , inner courts , and permanent partitions separating tenants, (d) Roof coverings shall be fire-retardant. ( e) Buildings of one-hour fire-resistive construction or of all metal construction used for the servicing of motor vehicles may be allowed, provided that no exterior wall shall be less than 20 feet from any property line other than an abutting public street of 20 feet or more in width. Section 3 :(a)In the fire zone the distance between exterior walls and the nearest property line other than a public thoroughfare of 16 feet or more in width shall be not less than that listed in the following table: Less than one-hour fire-resistive not permitted One-hour fire-resistive not permitted Two-hour. fire-resistive 3 feet Three-hour. fire-resistive 2 feet Four-hour fire-resistive No restriction (b) The exterior walls of buildings which are located outside the fire zone and which are built less than 5 feet from adjacient property lines other than one abutting a street shall have no openings therein and shall be not less than one-hour fire- resistive construction. Section All electrical wiring shall conform to the provisions of the Oregon State Electrical Code, as provided for in Title 112, Chapter 6, O.C.L. A. (13) 1 • PART VI SANITATION AND HEALTH Section 35: All plumbing shall comply with the requirements of the plumbing code of the State of Oregon, as provided for in Title 99, Chapter 16, O.C.L.A. and with the state and local board of health regulations. Section 36 : Every dwelling unit to which running water and sewerage "'are available shall be provided with not less than one water closet, one bathtub or shower, one lavatory, and one kitchen sink. Section 37 : Every habitable room shall have openings to the exterior with an area through which light may pass of not less than 10 per cent of the floor area. Exterior doors and windows shall open to the extent of not less than 5 per cent of the floor area. Windows shall face unobstructed, uncovered, horizontal areas of at least the extent of the glass of all windows opening thereon, no dimensions of which shall be less than 5 feet. Every bathroom or water closet compartment shall be provided with an outside window having a glass area of not less than 3 square feet and a ventilating area of 50 per cent of the glass area, or a skylight which will provide equal ventilation. Section 38: (a) Minimum area : Living rooms shall have an area of not less than 150 square feet or not less than 160 square feet when dining space is included and not less than 22o square feet when dining and cooking space is included, provided that this area shall be hot less than 210 square feet when located in a dwelling unit having less than two bedrooms . The area of the kitchen shall be not less than 60 square feet or not less than 90 square feet when dining space is included, provided that the area of the kitchen shall be not less than 50 square feet when located in a dwelling unit having less than two bedrooms. The area of at least one bed room shall be not less than 100 square feet. The area of any other habitable rooms shall be not less than 70 square feet. (b) Minimum height: Habitable rooms shall have a clear height of not less than 7 feet 6 inches , provided that rooms in the half story shall have a clear height of 7 feet 6 inches for at least one-half their area. In computing the area of rooms in half- stories , all portions less than 5 feet in height shall be dis- regarded. (c) Minimum Width: Habitable rooms, except kitchens , shall be not less than 7 feet wide in every part. (d) Rooms below grade: Ho room which has less than 50 per cent of its height above the average adjoining finished grade shall be occupied as a habitable room. This section shall not be con- strued to prohibit a play or recreation room below grade. (i4) • • • PART VII CONSTRUCTION DETAILS Section 39 : The drawings in PART VII are for the purpose of. Illustration and are not to be construed as limiting building practices to the methods shown. Other methods and proceedures which are commonly recognized by qualified persons as being satis- factory practice are acceptable if they do not conflict with the provisions of this code. In any event, all construction shall be fabricated and fastened in a workmanlike manner and in accordance with standard practice. (15) CEMENT CAP FLUE : CRICKET ... s •\ / SHINGLES FLASHING -- L-- FIG. IA. Eimmii <:::: 1> i TRIMMER JOIST FIG. I B I , HEADER / JOIST) NOTE ALL SPACES BETWEEN WOOD MEMBERS AND MASONRY ARE 2° AND ARE TO BE FILLED WITHNs II INCOMBUSTIBLE MATERIAL FIG. IC "<> ‘< >--e--- ASBESTOS BOARD IIICONSTRUCTION II DETAILS \1_f, , • p 2'" SPACE -------- FLUE .„... ../i,,, .. // ` CORBEL • PLASTER NOTE= ALL SPACES BETWEEN WOOD FRAME SMOKE AND MASONRY TO BE FILLED WITH , / CHAMBER ' i INCOMBUSTIBLE MATERIAL ✓✓✓:// III J/J IIIFIG. i / DAMPER ) fAESTOS / //// BOARD i i FINISHED FLOORIII '♦ FIRE BRICK �; ( ♦♦♦ `, / ' ASH DUMP e ♦♦ .. HEARTH 4"SPACE DIAGONAL SUB FLOOR CANTILEVER CROSS BRACE DOUBLE TRIMMER DOUBLE HEADER e 'o i •�i L METAL ,,N,,,, SUPPORT ,•••••::-....(0., 001,001 II:. ..'. ' /Al ASH PIT 4 TAIL JOIST CONCRETE0 SMOKE PIPE SLAB THIMBLE I8"BELOW JOISTS FIG. I E (MIN.) / CLEAN OUT "I / ‘< '' li II l'ir>th'41 o. a I 0 j.11)1 A:::;..::. CONSTRUCTION ''''7,z7 .7 / DETAILS BASEMENT FLOOR (17) • PLATE III I" X 4" KNEE BRACE LET INTO fX4� STUDS BRACE FIG. 2A a ' ,.,... •, ..____ LI(SO— D BRIDGIN a" FIRE STOP / CROSS /. , BRIDGING e�ir HEADER ► JOIST I / , ____,, STUD BOLT-IF JOIST +► SUB FL00' Illi ,. o FIRE STOP 2"X 6° PLATE SILL SILL SOLID SILL DETAIL FIG. 2B .11 CONSTRUCTION NOTE: DETAILS DIAGONAL SHEATHING MAY BE SUBSTITUTED FOR NOTCHED-IN BRACING RIDGE FIRE STOP FIG. 38 FIG. 3A EAVES DETAIL FIRE STOP FIG. 4A 4B FIG. PARTITION AT RIGHT ANGLES TO JOISTS PARTITION PARALLEL TO JOISTS FIG.4 D FIG.4C 1 s I FIG.6AI •!�� JOIST FRAMING \ I INTO BEAMS AND `I RESTING ON FIG.5 WOOD CLEATS POST SOLID CORNER \ `BUILDING FE DETAILS e� \1 0 d CONSTRUCTION \ FIG.6B POST FOOTING DETAIL DETAILS (19) ALTERNATE METHODS OF BRACING LONG RAFTERS FIG.7A COLLAR BEAM BRACE JOIST IPLATE DIAGONAL SHEATHING BUILDING PAPER I' BRIGK I FIG.7B METAL TIES METHOD OF TIEING BRICK VENEER TO WOOD FRAME ,•,• FIG.7C • JOIST Fl G.8 METAL TIE BEARING PLATE CONSTRUCTION METHOD OF FRAMING WOOD JOISTS DETAILS INTO MASONRY WALLS I• • PART VIII SET BACK LINES Section 40: It shall be unlawful for any person, persons, company or corpor- ation to erect or locate a building or any structure on any lot in a residence district unless the same be set back from the street in front thereof in line with the average line of the residences established on the same side of the street in said block, if same be built up, and if the block be not built up, to a line not less than 20 per cent of the depth of such lot. n case of corner lots it shall also be back from the side street line not less than 25 per cent of the width of such corner lot. Provided however that in no case shall the set-back from the side street be less than 15 feet and, provided further, that any struc- ture other than a residence erected on any corner lot shall be set back from the side street to a line not projecting beyond the front line of the house facing on said side street, if same shall be built up and if not built up said structure shall not be in front of the set-back line for residences on said side street. This provision may be modified and the building or other structure located nearer the street if such person; persons , company or corporation first obtain consent in writing of the owners or their authorized agents owning a majority of the frontage of property in the block on the side of the street on which said lot has a frontage. Section 41: It is hereby adjudged and declared that existing conditions are such that this Ordinance is necessary for the imm- ediate preservation of the public peace, health and safety; and an emergency hereby is declared to exist and this Ordinance shall take effect and be in full force and effect from and after its date of passage. Passed by the Common Council and signed by me in open session in authentication of its passage this 6th day of March , 1950 Mayor Approved by me this 6th day of March , 1950 ATTEST: Mayor City Recorder (21)