THE BUILDING CODE
of
THE CITY OF CENTRAL POINT OREGON
,
,
•
•
ORDINANCE NO. 289 -
AN ORDINANCE REGULATING THE CONSTRUCTION, ALTERATION, REPAIR AND
MOVING OF BUILDINGS WITHIN THE CITY OF CENTRAL POINT PROVIDING
FOR PERMITS AND FEES THEREFOR; PROVIDING FOR PENALTIES FOR VIO-
LA TION THEREOF; AND PROVIDING FOR THE REPEAL OF ALL ORDINANCES
OR PARTS OF ORDINANCES IN CONFLICT HEREWITH.
THE PEOPLE OF THE CITY OF CENTRAL POINT DO ORDAIN AS FOLLOWS :
PART I
ADMINISTRATION
Section 1:
This Ordinance shall be known and cited as"The Building Code of
The City of Central Point, Oregon'.
Section 2: The purpose of this code is to establish and enforce
minimum standards of safe design and construction forall structures
hereafter erected, altered, repaired, or removed within the limits
of the City and to promote the public health, welfare and safety.
This code shall invoke the police power specifically or impliedly
delegated to the City, and shall be liberally construed to effect
its purpose. The requirements of this code shall be deemed to
supplement the laws of the state and all ordinances, rules , and
regulations pertaining to use, occupancy, fire hazard, safety and
sanitation.
/ Section 3 : No structure or part of a structure shall hereafter
be built, altered, repaired or moved until a building permit there-
for has been granted by the building official. All structures
hereafter built, repaired, altered, or moved are subject to inspec-
tion by the building official. The building official shall have
the right of entry at any convenient time for the purpose of en-
forcing the regulations contained in this code.
Section 4: The construction details are included in this code as
part VII.
Section 5: The office of building official is hereby created.
The building official shall be appointed by the Mayor with the con-
sent of a majority of the council. he is hereby charged with the
administration and enforcement of this code.
Section 6: Application for a building permit shall be filed by
the owner or his agent with the building official upon a form pro-
vided for the purpose and giving such information as the building
official shall require. Such application shall be accompanied by
two complete sets of plans and specifications including plot plans
showing the relationship of the proposed building to abutting
property lines and buildings. if, in the opinion of the building
official, the c h-a ratter of the work is sufficiently described in
the application, he may waive the filing of plans provided the
cost of such work does not exceed one thousand dollars (4$1,000) .
Section 7 : If the building official finds that the proposed
building will comply in every respedt with this code and the laws
of the state of Oregon, he shall issue a building permit therefor,
and shall write "approved" on one set of the plans and specifica-
tions , which shall be kept at the site of the proposed building.
After issuance of the building permit, the plans and specifications
shall not be altered unless such change is approved by the build-
ing official as conforming to this code.
(1)
1
Section 8: The building official shall order a stoppage of work
on any type of construction for which a permit is required at any
time that he finds the provisions of this code, or plans and speci-
fications approved under this code, are not being complied with.
He shall post a copy of this order at the site of construction and N
serve a copy thereof upon the permittee or his agent. Upon receipt
of this order the permittee or his agent shall forthwith cease work.
The building official shall not lift such order until supplied with
satisfactory evidence that the violation is corrected. The building
official shall serve notice upon the permittee or his agent that the
stop work order has been lifted before work may be resumed. Stop
work orders shall be in addition to other penalties provided for
violations of this code.
Section 9 : A building permit shall become void unless operations
are commenced within six months from date thereof unless such time
is extended by the building official.
Section 10: The building official shall be notified by the holder
of the permit, and the building official shall inspect the build-
ing,
1. When the foundations are ready to be placed.
2. When the foundation is completed and before sub-floor
is laid.
3. When the structural frame is complete.
4. when the building is completed.
Section 11. A building board of appeals is hereby created. It
shall consist of three members who are qualified by experience and
training to pass on matters pertaining to building construction. It
shall be appointed by the mayor with the consent of a majority of
the Council, and shall hold office at the pleasure of the Mayor.
The building official shall act as secretary of the board of appeals ,
and shall keep a record of its decisions.
Section 12 : Any person who feels that an injustice has been done
him by any order ox4 ruling of the building official may appeal there-
from to the board of appeals by filing a written notice of his appeal
with the building official within ten days after receipt of the order
or ruling complained of. the decisions of said board shall be limi-
ted to the interpretation of the provisions of this code. It shall
adopt rules of proceedure for matters coming before it and its dec-
isions shall be governed by a majority vote. It shall render its
findings and decisions in writing, one copy thereof to be filed with
the building official and one copy to be delivered to the appellant.
The decisions of the board shall be conclusive except in case of
mistake or fraud. The board may recommend to the city Council any
amendments to this code or new legislation that it may deem advis-
able.
Section lai Before receiving a building permit for a group I or
11/ group II building as hereinafter defined, the owner or his agent
shall pay the City Recorder the following fees :
No fee for work the value of which is less than fifty dollars.
One (S1.00) dollar for work the value of which is more than
fifty ( 50) dollars but less than five hundred ( 500)
dollars.
Two (2) dollars for work the valuation of which is more than
five hundred ( 500) dollars but less than one thousand
(1,000) dollars.
Two (2) dollars for each additional one thousand (1,000) dollars
or fraction thereof of total valuation up to fifteen thou-
sand (15,000) dollars.
(2)
•
One (1) dollar for each additional one thousand (1,000)
dollars or fraction thereof of total valuation over
fifteen thousand (15,000) dollars
i/Ten (10) dollars for moving a building.
The City, county, state, or the United States shall be exempt from
paying fees for a building permit.
Section 1 -: New materials , systems of construction, and devices
may be approved by the building official when they are determined
to be equal to those required in this code. The building official
shall be guided in such approval by the results of tests conducted
by the testing laboratories of the National Bureau of Standards ,
The Underwriters Laboratories , Inc. , or by any other testing agency
or committee whose standards conform with the above agencies.
Section 15: Any alteration to the structural portion of any build-
ing or any alteration necessitated by a change in type of occupancy
resulting in an increased floor load shall conform to the require-
ments of this code. All buildings and structures now existing or
hereafter erected shall be maintained in a safe condition.
L, Section 16: Every application for a permit to move a building
shall designate the site of the building to be moved and the site
to which the building is to be moved. Permission to use the pubic
streets shall be obtained from the proper authority.
c, Section 12i Any person, firm, or corporation who violates or
refuses to comply with any provision of this code shall be deemed
guilty of a misdemeanor and shall be punished by a fine of not
more than. One hundred (100) dollars , or by imprisonment, of not more
than thirty (30) days , or by both such fine and imprisonment for
each provision violated. It shall be the responsibility of the
offender to abate the violation and each day that such violation is
permitted to exist shall constitute a separate offense.
Section 18 : Should any section or provision of this code be dec-
lared by a court of competent jurisdiction to be invalid, such
decision shall not affect the validity of the code as a whole or
any part thereof other than the part so declared to be invalid.
Section 121 All Ordinances or parts of Ordinances in conflict
with the provisions of this code are hereby repealed.
PART II
DEFINITIONS
Section 20: In the interpretation of this code, the following
definitions shall be used;
Alteration means any change or addition in constructuin or arr-
angement or any change in type of occupancy.
Building means any structur constructed for the shelter of persons,
animals, or property of any kind.
Court means an unoccupied space extending to the sky from the ground
or from the roof of a lower portion of a building, such space being
adjacient to the building and enclosed on two or more sides by walls
of the building.
Dwelling means a building or that part of a building arranged or
occupied as the home or sleeping place of one or more persons.
(3)
•
•
•
Gara. e means a building which affords shelthr to a motor vehicle
uding a volatile flammable liquid as a fuel.
Grade of a building means the established or finished ground ele-
vation. this is used in determining the number of stories and
height of the building.
If a building wall is built up to or within five feet of a street
lot line, the grade is determined by the sidewalk elevation at the
center of the length of the wall fronting on such sidewalk. If the
building has two or more such walls, the grade shall be the aversge
of the sidewalk elevations at such points.
If the building walls are more than five feet from the street lot
line, the grade shall be the average of the finnished ground ele-
vations at each wall of the building, measuring each elevation of
the ground at the center point of the length of the wall.
Habitable room means a room occupied or arranged for living, eat-
ing, or sleeping purposes , including kitchens for family units or
individual households, but not including bath or toilet rooms ,
laundries , pantries, corridors, or recreation rooms.
Height of building means the vertical distance from the grade of the
building to the highest point in the coping of a flat roof or to the
deck line of a mansard roof or to a point halfway between the eaves
and the highest ridge of a roof.
Loads. Live loads mean the load carried by a building or structure
not including the weight of any part of the building orstructure
and not including any loads caused by wind, earthquake, and later-
ally exerted pressure of earth or other materials, liquids or gasses.
Bead loads mean the actual weight of roof, walls , floors ,
partitions, and other permanent parts of building.
Masonry means units of brick, stone, concrete, tile or terracotts
laid in mortar and includes monolithic concrete.
Repairs means the reconstruction or renewal of any part of a build-
ing or structure for the purpose of its maintenance. The word
"repair" does not apply to any change of construction. See alter-
ation.
Story means that part of a building between the upper surface of
a floor and the upper surface of the floor next above except the
top story which is that part included between the upper surface
of the top floor and the ceiling or if there is no ceiling, the
underside of the roof.
Wall means the vertical structural members of a building which en-
close it, form its courts , or form its vertical fire divisions.
Wall, bearin . Bearing wall means a wall which carries dead loads
other than its own weight.
Wall, fire, means a wall of four-hour fire-resistive construction
which divides a building or separates buildings for the purpose of
restricting the spread of fire and which starts at the foundation
and extends continuously through all stories to and above the roof.
But where the roof is fire-proof or semi-fireproof the wall shall
be carried up tightly against the underside of the slab.
Wall, non-bearing. ITon-bearing wall means a wall which supports
no load other than its own weight.
Wall, party. Party wall means a wall which separates two or more
buildings or is built to be used jointly by separate buildings.
(4)
PART III
CLASSIFICATION
Section 21: For the purpose of this code all structures shall be
classified in one of two groups :
Group I. Those structures whose construction is completely covered
by this code :
(A) Buildings used as single or two-family dwellings constructed
of frame construction not exceeding two stories in height
with or without an attic, or of ordinary masonry construc-
tion not exceeding one story in height with or without an attic.
(B) Buildings used for stores , offices , shops , or warehouses
not exceeding one story or 25 feet in height.
Dry-cleaning establishments, garages accomodating over four
(4) cars , and places of assembly or detention shall be reg-
ulated as group II buildings.
(C) Private Garages not exceeding one story in height of frame
or ordinary masonry construction with a capacity of not more
than four (4) cars, wood sheds , chicken houses, and other
similar buildings accessory to those allowed in parts (A)
and (B) of this section.
Buildings designated in parts (A) , (B) and (C) of this section
involving a ground area in excess of 4,000 square feet or the
use of structural reinforced concrete, structural steel, heavy
mill construction, or roof trusses , shall be regulated as group
II buildings , except that the incidental use of steel beams,
columns, lintels , and hangars and of reinforced concrete slabs
shall be permitted in group I buildings.
Group II. All structures not included in group I shall be classi-
fied as group II.
Section 22 : All Group II buildings , unless otherwise provided in
this code, shall conform to all of the provisions , except Part I
(Administrative) and Part IV ( Requirements Based on Location in
Fire Zones) , of the 1949 Edition of the Uniform Building Code,
prepared by the Pacific Coast Building Officials Conference, which
is hereby made a part of this code and adopted by reference. One
copy of said code shall be placed on file in the office of the
building official for public use and inspection and shall be mar-
ked "Official Coil" .
,A11 Group II buildings shall be designed by, and their construction
V shall be supervised by an architect or engineer registered in the
State of Oregon. Upon completion of a structure, such architect
or engineer shall be required to make and file with the building
official an affidavit stating under oath that the provisions of
this code have been complied with.
( 5)
PART IV
STANDARDS OF DESIGN AND CONSTRUCTION
Section 23 : The minimum live loads per square foot for floors and
roofs shall be as follows :
(a) Floors (Minimum live loads in lbs. per square foot)
Private dwellings , dormatories , hotels , guest rooms , apart-
ments, and hospital rooms 40
Offices and assembly rooms with fixed seats 50
Public rooms,corridors , balconies , and public stairways. . 100
All floors other than the above shall be designed for
actual loads, but in no case less than 100
(b) Roof load per square foot of horizontal projection 30
Section 24: All measurements of dimension lumber given in this
code are nominal unless otherwise noted.
(a) The minimum thickness of floor or roof beams , joists, or rafters
shall be 2 inches.
(b) The ends of joists , beams rafters , and girders entering masonry
walls shall be beveled 3 Inches in 12 inches from the vertical,
with 1 inch air space on each side and on the top. Such members
shall be tied to the wall with a metal anchor once in every 8
lineal feet of wall and shall have not less than 32 inches of
bearing.
(c) In frame construction, sills shall be anchored to the foundation
walls at 6 foot intervals or less by bolts not less than inch
in diameter embedded at least 6 inches in the foundation walls.
(d) the Maximum spacing of floor joists shall be 16 inches center
to center.
(e) Maximum allowable spans for joists and rafters, as designated
in the table, are based on fiber stress of 1200 lbs. per square
inch and on the following maximum allowable live loads :
Floor joists 40 lbs. per square foot
Ceiling joists , , . . none
Roof rafters 30 lbs. per square foot
if flooring is to be installed over ceiling joists, they shall
have the same allowable spans as floor joists.
(6)
r.. • ! -
Size Spacing Floor joists Floor joists Ceiling Rafter
plastered unplastered joists span
below below
2"x4" 12" 11'-0" 8'-10"
16" 10'-0" 7t- 8"
24" 8'-1_t" 6 '- 4"
2"x6" 12" 10'-8" 12 '- 0" 161- 7" 13g- 6"
16" 9 '-6" 10'- 0" 15'- 4" 11 '-10"
24" 13 '- 8" 9 '- 9"
2"x8" 12" 14'- 1" 15'-11" 21'- 8" 17'-10"
16" 12 ' 11" 13 '-11" 20'- 2" 15'- 7"
24" 181- 0" 12 '-11"
2"x10" 12" 17'- 9" 19t-11" 26 '-10" 22'- 4"
16" 15'-10" 17 '- 4" 25t- 0"" 19 '- 7"
24" 22'- 6" 16I- 3."
2"x12" 12" 21'- 4" 23 '-11"
16" 10 '- 1" 20'-11"
2"x14" 12" 24'-11" 27'- 8"
16" 22 '- 4" 2+' - 4"
3"x6" 12" 12 ' - 4" 15'- 0"
16" 11 '- 3" 131: 1"
3"x8" 12" 16 '- t+" 19 '- 8"
16" 14'-11" 19 '- 4"
3"x10" 12" 20'- 6" 24 '- 7" p~
16" 18 '-10" 21'- 8"
3"x12" 12" 2 1-'- 6" 29t- 4"
16" 22 '- 7" 25'-11"
3"x14" 12" 2.8 '- 7" 30'- 6"
16" 26 '- 4" 30'- 3"
Note: A fiber stress of 1200 lbs. per square inch applies to
Douglas Fir and Southern Pine of a structural grade. For
woods having a fiber stress of 1000 lbs. per square inch
to 1200 lbs. per square inch, reduce the span 1/6th. No
wood having a fiber stress less than 1000 lbs. per square
inch shall be used as a structural member. Joists supp-
orting loads greater than 40 lbs. per square foot shall
be designed in accordance with standard practice.
(f) Joists or rafters not resting on masonry shall be supported
on bearing partitions or by beams, girders, hangers , or trusses.
(g) Joists and rafters may be notched at the support but such notch
shall not exceed 1/5th the total depth of the joist or rafter.
(h) Where live loads do not exceed 50 lbs. per square foot, a
wooden strip at least 2" by 4" , strongly spiked or bolted to
the girder, may be used to support joists or rafters.
(i) Header joists over 6 feet long and tail joists over 12 feet
long shall be hung in joist or beam hangers or secured by other
devices affording equivalent support. Trimner and header joists
more than 4 feet long shall be doubled.
( j) All floor joists shall be bridger once in every 8 feet of span.
Each member of wood cross bridging shall be not less than 1 inch
by 4 inches.
(k) Girders supporting wood joists carrying a 40 lb. per square
foot live load shall be not less than 4" by 4" (actual dim-
ensions) for spans up to 5 feet and not less than 4" by 6" (
(actual dimensions) set on edge, for spans fron 5 feet to 7
feet. Girders for longer spans or greater loads shall be
designated according to approved practice.
(1) All wood shingles shall be nailed firmly with copper, zinc,
zinc coated, or commercially pure iron nails of at least 14B
and S guage and shall be not less than 1-_ inches in length.
(7)
.
•
Each shingle shall be nailed with not less than 2 nails driven
substantially into the supporting roof construction.
Maximum exposed length of wood shingles :
16" shingle 5" ( 5" to the weather)
18" shingle 52' ( 5i" to the weather)
24" shingle 7z' (72" to the weather)
(m) All wood joist used to frame over unexcavated areas shall
have a clearance of not less than 18 inches above the sur-
face of the ground.
Section 25:
(a) The minimum size of an exterior wall or bearing partition
stud shall be two inches by four inches .
(b) The maximum spacing between centers os studs shall be 24 inches.
(c) Flat studs shall not be used in exterior or bearing walls
except where such walls are constructed double to receive a
sliding door.
(d) The exterior stud walls of all wood frame buildings of more
than one story in height shall be diagonally braced at the
corners by notching into the studs a 1 inch by 4 inch brace
at an angle of 45 degrees except that it shall be optional to
omit these braces if the studs are covered with boards apnlied
diagonally.
( e) All partitions shall be framed solid at the corners so that no
lath may extend from one room to the other.
(f) Frame buildings may be veneered with masonry but such veneer
shall be not less than 4 inches thick and shall be anchored to
the wood frame or backing at intervals not exceeding 18 inches
vertically and 16 inches horizontally by standard galvanized
wall ties. The height of such veneer construction shall in no
case be more than 20 feet above the grade of the building, and
shall be carricd, on the foundation wall.
Section 26 : Fire stopping shall be provided to cut off all con-
cealed draft openings both vertical and horizontal, and to form an
effective barrier between stories and between the top story and the
roof space. It shall be used in specific locations as follows :
(a) In exterior or interior stud walls at ceiling and floor levels.
(b) In all stud walls and partitions , including furred spaces , so
placed that the maximum dimension of any concealed span is
not over lo feet.
(c) In furred masonry walls .
(d) Between stair stringers at least once in the middle portion
of each run, at the top and bottom and between studs, along
and in line with run of stairs adjoining such partition.
( e) Around top and bottom, aides and ends of sliding door pokets.
(f) Spaces between chimneys and wood framing shall be solidly filled
with mortar, loose cinder, or other incombustible material which
shall rest on incombustible supports.
(g) Any other location not specifically mentioned above, such as
holes for pipes, shafting, etc. , which could afford a passage
for flames.
(h) Clothes chutes, wood hoists , and similar devices shall be
equipped with self closing doors at all access points.
(8)
•
•
Fire stops, when of wood, shall be 2 inches thick. If width of
opening is such that more than one piece of wood is necessary,
there shall be two thicknesses of 1 inch material with joists
broken.
Floor joists in all types of construction shall be fire stopped
at the end, and over supports for the full depth of the joists.
No fire stopping shall be covered or concealed until inspected by
the building official.
Section 27:
(a) Flue linings shall be manufactured from fire clay or other
suitable refractory clgys and shall have a softening point not
lower than 1994° Fahrenheit. Flue linings shall have a minimum
thickness of 5/8 inches and shall be carefully bedded upoi one
another in mortar with all joints left smooth on the inside.
Masonry shall be laid up with mortar around each successive length
of lining as it is set. all joints and spaces between masonry and
lining shall be completely filled as each course of masonry is laid.
No defective linings shall be used. Linings shall start 8 inches
below the smoke pime intake or in the case of a fireplace from the
apex of the smoke chamber and shall be continuous to the top of the
chimney. no smokepipe intake shall be cut into a flue lining which
is already set in place.
(b) Mortar is defined as follows :
Ratio by volume
Cement Lime Sand
Cement lime mortar. . . . 1 1 6
Portland Cement Mortar 1 4 3
Mortar used between joints of flue linings and in portions of
the chimney above the roof or otherwise exposed to the weather
shall be Portland Cement Mortar.
Firebricks used for the lining of flues or facing of fireplaces
shall be laid in fire clay mortar. Other parts of the chimney
shall be laid up in cement lime mortar.
(c) The walls of brick chimneys shall be built of solid brick and
shall be not less than 3 3/4 inches thick and shall be lined,
except that such lining may be optional. in residences if the
walls are increased to 6 inches in thickness.
(d) All brick shall be laid with full, push filled cross and bed
mortar joints and shall be struck smooth where exposed to the
weather.
( e) Concrthte chimneys cast in place shall be suitably reinforced
vertically and horizontally. The walls shall be not less than
3-3/4 inches thick and shall be lined, except that such lining
may be optional in residences if the walls are increased to
6 inches in thickness.
(f) All stone chimneys shall be lined. Minimum thickness for walls
of a dressed stone chimney shall be 8 inches. Minimum thickness
for walls of other stone chimneys shall be 12 inches.
(g) Masonry and concrete walls of buildings may form part of a
chimney when the chimney walls are securely bonded into the
walls of the building and when the flue is lined the same as
in independent chimneys. Flues in party walls shall not extend
beyond the center of the wall.
(h) Hollow tile or hollow concrete blocks shall not be used for the
walls of an independent chimney, but may be used for chimneys
built as a part of an exterior wall of hollow masonry, in
which case the chimney walls shall be at least 8 inches thick,
and shall be lined.
(9)
( i) Chimneys shall be built at least 3 feet above a flat roof
and at least 2 feet higher than the highest elevation of any
portion of the building within 10 feet of the chimney.
( j) Chimneys shall be built from the ground up and shall rest on
concrete or solid masonry foundations. The footing of an
exterior chimney shall start below the frost line and shall rest
on undisturbed soil. Such footings shall be at least 8 inches
thick and extend at least 6 inches beyond the face of the
chimney wall.
(k) Corbeled chimneys shall be supported by solid masonry walls
at least 12 inches thick and the corbeling shall not project
more than 1 inch per course and not more than 6 inches in any
case.
(1) No flue shall be built at an angle greater than 30° with the
vertical.
(m) Not more than 2 lined flues shall be permitted in the same
flue space and the joints of any such adjoining flue linings
shall be staggered at least 7 inches.
(n) Fireplace walls shall be not less than 8 inches thick, and if
built of stone, not less than 12 inches thick. The faces of
all such minimum thickness walls exposed to fire shall be lined
with firebrick, soapstone, cast iron, or other fire-resistive
material. When lined with 4 inches of firebrick, such lining
may be included in the minimum thickness.
All Fireplaces shall have trimmer arches , reinforced concrete
cantilever slabs , or other approved fire-resistive construc-
tion supporting the hearth, and the hearth shall estend not
less than 20 inches from the face of the chimney wall and shall
be not less than 8 inches wider than the fireplace opening on
either side. The flue area of a fireplace shall be not less
than 1/12th of the area of the fireplace opening.
( o) Minimum flue sizes:
Rectangular Rectangular Circular
Lined flue unlined flue flue
Small stoves and heaters 8"x 8" 8"x 8" 6"dia.
Stoves, ranges, and heater 8"xl2" 12"x12" 8"dia.
rooms
Warm air furnaces, steam 12"x12" 12"x12" 10"dia.
and hot waste boilers
(p) Smokepipes shall enter the side of a chimney through a fire
clay or metal thimble or flue-ring of masonry. The top of the
smokepipe shall be at least 18 inches below the ceiling or
joists . No woodwork shall be placed within 6 inches of a
thimble. No intake pipe or thimble shall extend into the flue.
(q) No wooden beams, joists , or rafters, or studs shall be placed
within 2 inches of chimney walls and no woodwork shall be
placed within 4 inches of the back of any fireplace. All ppaces
between chimneys and members of the wood frame shall be filled
with incombustible material supported by strips of sheet metal
or metal lath set in the brick work and nailed to the wooden
members.
(r) Gas appliances using more than 5000 B.T.U. per hour shall be
connected to an effective flue or outlet pipe opening to the
outer air. Such flue shall be either a lined chimney or an
outlet pipe of incombustible, noncorrodible material with bell
and spigot or other acceptable joints. Such pipes, when located
inside frame walls, shall have 1 inch clearance from all wood
construction and shall be encased in an incombustible jacket.
( s) The use of porcelain enamel or other types of flues , which are
approved by the Underwriters Laboratories Incorporated, shall
be permitted under this code.
(10)
Section 28 :
-7 The minimum thickness of exterior walls and bearing walls of
masonry shall be as follows :
1. Cavity wall masonry 10"
2. Stone masonry (Ashlar) 12"
3. Stone masonry (Rubble) 16"
4. Other I Masonry walls when used in 1 story single-family
dwellings and one story private garages not over 9 feet in
height, provided that when gable construction is used
an additional 6 feet is permitted to
the peak of the gable 6"
5. Other masonry walls under conditions other than
those specified in section 4 8"
(b) The minimum thickness of interior non-bearing partitions
of masonry shall be 4 inches.
(c) In plain masonry of brick, all stretcher courses shall be
bonded by making vertical joints over the centers of stretchers .
Every sixth course shall be a header course and in no case shall
there be less than one header in every 72 square inches of wall
surface. If the thickness of the wall is greater than the
length of one header, each header shall be covered by another
header that breaks joints with the header below.
(d) In plain masonry of stone, the bond stones shall be uniformly
distributed throughout the wall and shall comprise not less than
20 per cent of the wall surface. There shall be atleast one
bond stone for every five stretchers and each bond stone shall
extend through the wall.
Section 29:
(a) Footings and foundations shall be constructed of solid masonry
or of reinforced concrete and shall extend 6 inches below the
frost line measured from the finished grade and to undisturbed
soil, except that reinforced concrete footings and foundations
may rest on fill when installed according to recognized good
practice.
(b) In no case shall the thickness of a foundation wall be less than
the wall above, except that a masonry veneer wall may project
not more than 3/4 inches beyond the outside face of the support-
ing wall. No brick masonry, coursed stone, or concrete found-
ation walls shall be less than 8 inches thick except that in. a
1 story frame dwelling or frame business building where the
basement does not have a distance below ground exceeding 5 feet,
a concrete foundation wall shall not be less than 6 inches
thick. Any masonry in foundations or in walls in contact with
the earth shall be laid with Portland cement mortar.
Foundation walls supporting wood or light steel structural mem-
bers shall extend at least 6 inches above the finished ground
level.
(c) Footings shall be acceptable without computation of the unit
pressure under them if they have a minimum projection of four
inches from all faces of the wall, column or pedestal, and if
their depth is at least equal to their projection and never
less than 6 inches.
(d) Concrete floor slabs installed on the ground and driveway slabs
shall be not less than 4 inches thick.
(11)
•
•
( e) The space beneath a building not having a basement shall be
enclosed by a concrete or masonry wall which shall extend
from at least 6 inches above the finished grade to 6 inches
below the frost line measured from the finished grade and to
undisturbed soil. Such space shall be ventilated by at least
two screened openings arranged so that air can circulate.
The area of such openings shall be not less than 2 square
feet for each 25 lineal feet or fraction thereof of exterior
wall.
PART V
FIRE AND SAFETY
Section 30: There is hereby established a fire zone which shall
embrace that portion of THE CITY OF CENTRAL POSIT described as
follows :
Beginning at the center of the intersection of Pine and Fifth
Streets and running thence Southeasterly along the center line of
Fifth Street to the center line of Oak Street; thence Southwesterly
along the center line of Oak Street to the Center line of South
First Street; thence Southeasterly along the center line of First
Street to its intersection with the South City Limits line; thence
West along the City Limits line to the Westerly line of the South-
ern Pacific Company property; thence Northwesterly along the
Southern Pacific Company property line to its intersection with the
West City Limits line; thence North to the Easterly line of the
Southern Pacific Company property; thence South easterly along the
Southern Pacific Company property line to the north City Limits line;
thence East to the Center of North First Street, extended; thence
Southeasterly along the center line of First Street to the center
of TManzanita Street; thence Northeasterly to the center of Fifth
Street; thence Southeasterly to the point of beginning.
Section 31: Any existing building within the fire zone which be-
/ comes damaged to an extent of 50 per cent of the replacement value
be-
t/ of the date of the damage, by fire, decay, or otherwise, shall
not be rebuilt unless the entire building when so rebuilt will
conform to this code. When damage thereto is less than 50 per cent
of the replacement value thereofas of the date of the damage, the
structure shall not be rebuilt to a elevation higher than the highest
part left standing after such damage shall have occurred, or so as
to be in better state of repair or to occupy a greater space than
before it was damaged. The extent of the damage that has been done
to any such building by fire, decay, or otherwise, shall be deter-
mined by three disinterested persons, residents of The City of
Central Point, one of whom shall be selected by the owner or agent
of the building, the second by the City Council or authorized
official, and the two so chosen to select the third. The persons
so chosen shall fairly and impartially estimate the damage, and
their decision shall be final and binding upon all persons concerned.
(12)
•
Whenever any building shall be found to be damaged to an extent
of 50 per cent of the replacement value thereof, by fire, decay
or otherwise, notice of such finding shall be served in writing
by the City Council or an authorized official, on the owner or
agent of said building, and thereaftersaid building shall be and
the same is hereby declared, a public nuisance and shall be abated.
Failure of the owner or agent of said building to remove the same
within thirty (30) days after receipt of written} notice of the
finding hereinabove referred to, shall be fined in the sum of
not exceeding one hundred (100) dollars. Each day the same shall
be permitted to stand after the receipt of such notice in writing
and the expiration of said 30-day period, shall constitute a
separate offense. In case the owner after due notice fails to
remove or abate the structure within sixty (60) days after service
of notice, ?he City shall remove and abate said nuisance.
The Council shall ascertain and declare the cost of said work,
and assess the same against the property upon which said building
is located. Said assessment shall be declared by resolution, and
it shall be entered in the docket of City liens, and shall there-
upon be and become a lien against said property, and the creation
of said lien and the collection and enforcement of said cost shall
be done in substantially the same manner as in the case of cost of
street improvements, but irregularities of informalities in the
proceedure shall be disregarded.
Section 2 : Buildings hereafter erected, constructed, or moved
into the fire zone shall conform to the following minimum requir-
ments :
(a) Four-hour fire-restive construction - Fire walls and party ,
walls.
(b) Two-hour fire-resistive construction - Exterior walls.
(c) One-hour fire-resistive construction - Floors; roofs , stairs , ,
shafts , inner bearing walls , inner courts , and permanent
partitions separating tenants,
(d) Roof coverings shall be fire-retardant.
( e) Buildings of one-hour fire-resistive construction or of all
metal construction used for the servicing of motor vehicles
may be allowed, provided that no exterior wall shall be less
than 20 feet from any property line other than an abutting
public street of 20 feet or more in width.
Section 3 :(a)In the fire zone the distance between exterior walls
and the nearest property line other than a public thoroughfare of
16 feet or more in width shall be not less than that listed in the
following table:
Less than one-hour fire-resistive not permitted
One-hour fire-resistive not permitted
Two-hour. fire-resistive 3 feet
Three-hour. fire-resistive 2 feet
Four-hour fire-resistive No restriction
(b) The exterior walls of buildings which are located outside the
fire zone and which are built less than 5 feet from adjacient
property lines other than one abutting a street shall have no
openings therein and shall be not less than one-hour fire-
resistive construction.
Section All electrical wiring shall conform to the provisions
of the Oregon State Electrical Code, as provided for in Title 112,
Chapter 6, O.C.L. A.
(13)
1
•
PART VI
SANITATION AND HEALTH
Section 35: All plumbing shall comply with the requirements of
the plumbing code of the State of Oregon, as provided for in Title
99, Chapter 16, O.C.L.A. and with the state and local board of
health regulations.
Section 36 : Every dwelling unit to which running water and sewerage
"'are available shall be provided with not less than one water closet,
one bathtub or shower, one lavatory, and one kitchen sink.
Section 37 : Every habitable room shall have openings to the exterior
with an area through which light may pass of not less than 10 per
cent of the floor area. Exterior doors and windows shall open to the
extent of not less than 5 per cent of the floor area.
Windows shall face unobstructed, uncovered, horizontal areas of at
least the extent of the glass of all windows opening thereon, no
dimensions of which shall be less than 5 feet.
Every bathroom or water closet compartment shall be provided with
an outside window having a glass area of not less than 3 square
feet and a ventilating area of 50 per cent of the glass area, or a
skylight which will provide equal ventilation.
Section 38:
(a) Minimum area : Living rooms shall have an area of not less than
150 square feet or not less than 160 square feet when dining
space is included and not less than 22o square feet when dining
and cooking space is included, provided that this area shall be
hot less than 210 square feet when located in a dwelling unit
having less than two bedrooms .
The area of the kitchen shall be not less than 60 square feet
or not less than 90 square feet when dining space is included,
provided that the area of the kitchen shall be not less than 50
square feet when located in a dwelling unit having less than
two bedrooms.
The area of at least one bed room shall be not less than 100
square feet.
The area of any other habitable rooms shall be not less than
70 square feet.
(b) Minimum height: Habitable rooms shall have a clear height of
not less than 7 feet 6 inches , provided that rooms in the half
story shall have a clear height of 7 feet 6 inches for at least
one-half their area. In computing the area of rooms in half-
stories , all portions less than 5 feet in height shall be dis-
regarded.
(c) Minimum Width: Habitable rooms, except kitchens , shall be not
less than 7 feet wide in every part.
(d) Rooms below grade: Ho room which has less than 50 per cent of
its height above the average adjoining finished grade shall be
occupied as a habitable room. This section shall not be con-
strued to prohibit a play or recreation room below grade.
(i4)
•
•
•
PART VII
CONSTRUCTION DETAILS
Section 39 : The drawings in PART VII are for the purpose of.
Illustration and are not to be construed as limiting building
practices to the methods shown. Other methods and proceedures
which are commonly recognized by qualified persons as being satis-
factory practice are acceptable if they do not conflict with the
provisions of this code. In any event, all construction shall be
fabricated and fastened in a workmanlike manner and in accordance
with standard practice.
(15)
CEMENT CAP FLUE
: CRICKET
...
s
•\
/ SHINGLES
FLASHING -- L--
FIG. IA.
Eimmii
<:::: 1>
i
TRIMMER JOIST
FIG. I B
I ,
HEADER /
JOIST)
NOTE
ALL SPACES BETWEEN WOOD
MEMBERS AND MASONRY ARE 2°
AND ARE TO BE FILLED WITHNs
II
INCOMBUSTIBLE MATERIAL
FIG. IC
"<>
‘< >--e---
ASBESTOS BOARD
IIICONSTRUCTION
II
DETAILS
\1_f, ,
• p
2'" SPACE -------- FLUE
.„... ../i,,, ..
// ` CORBEL
• PLASTER
NOTE=
ALL SPACES BETWEEN WOOD FRAME SMOKE
AND MASONRY TO BE FILLED WITH , / CHAMBER
' i
INCOMBUSTIBLE MATERIAL ✓✓✓://
III
J/J IIIFIG. i / DAMPER
) fAESTOS
/
//// BOARD
i
i
FINISHED FLOORIII
'♦ FIRE BRICK
�; ( ♦♦♦ `, / ' ASH DUMP
e
♦♦ .. HEARTH
4"SPACE
DIAGONAL SUB FLOOR
CANTILEVER
CROSS BRACE
DOUBLE TRIMMER
DOUBLE HEADER
e 'o
i •�i L
METAL
,,N,,,,
SUPPORT
,•••••::-....(0.,
001,001
II:. ..'. ' /Al ASH PIT
4 TAIL JOIST CONCRETE0
SMOKE PIPE SLAB
THIMBLE
I8"BELOW
JOISTS
FIG. I E (MIN.)
/
CLEAN OUT "I /
‘< '' li II l'ir>th'41 o. a
I 0 j.11)1 A:::;..::.
CONSTRUCTION ''''7,z7 .7
/
DETAILS BASEMENT FLOOR
(17)
•
PLATE
III
I" X 4" KNEE
BRACE
LET INTO fX4�
STUDS BRACE
FIG. 2A
a ' ,.,... •, ..____
LI(SO— D
BRIDGIN a"
FIRE
STOP /
CROSS /. , BRIDGING e�ir HEADER ►
JOIST I /
, ____,,
STUD
BOLT-IF
JOIST +► SUB FL00'
Illi ,. o
FIRE STOP 2"X 6°
PLATE
SILL SILL
SOLID SILL DETAIL
FIG. 2B
.11 CONSTRUCTION
NOTE:
DETAILS DIAGONAL SHEATHING MAY BE SUBSTITUTED FOR
NOTCHED-IN BRACING
RIDGE
FIRE STOP
FIG. 38
FIG. 3A
EAVES DETAIL
FIRE STOP
FIG. 4A 4B FIG.
PARTITION AT RIGHT ANGLES TO JOISTS
PARTITION PARALLEL TO JOISTS FIG.4 D
FIG.4C
1 s I FIG.6AI •!��
JOIST FRAMING
\ I INTO BEAMS AND `I
RESTING ON
FIG.5 WOOD
CLEATS POST
SOLID CORNER \ `BUILDING FE
DETAILS e�
\1 0 d
CONSTRUCTION \ FIG.6B
POST FOOTING DETAIL
DETAILS
(19)
ALTERNATE METHODS OF
BRACING LONG RAFTERS
FIG.7A
COLLAR BEAM
BRACE
JOIST
IPLATE
DIAGONAL SHEATHING
BUILDING PAPER
I' BRIGK
I FIG.7B
METAL TIES
METHOD OF TIEING
BRICK VENEER TO WOOD
FRAME ,•,•
FIG.7C
•
JOIST
Fl G.8
METAL TIE
BEARING
PLATE
CONSTRUCTION
METHOD OF FRAMING WOOD JOISTS
DETAILS INTO MASONRY WALLS
I•
•
PART VIII
SET BACK LINES
Section 40:
It shall be unlawful for any person, persons, company or corpor-
ation to erect or locate a building or any structure on any lot
in a residence district unless the same be set back from the street
in front thereof in line with the average line of the residences
established on the same side of the street in said block, if same
be built up, and if the block be not built up, to a line not less
than 20 per cent of the depth of such lot.
n case of corner lots it shall also be back from the side street
line not less than 25 per cent of the width of such corner lot.
Provided however that in no case shall the set-back from the side
street be less than 15 feet and, provided further, that any struc-
ture other than a residence erected on any corner lot shall be set
back from the side street to a line not projecting beyond the front
line of the house facing on said side street, if same shall be
built up and if not built up said structure shall not be in front
of the set-back line for residences on said side street.
This provision may be modified and the building or other structure
located nearer the street if such person; persons , company or
corporation first obtain consent in writing of the owners or their
authorized agents owning a majority of the frontage of property
in the block on the side of the street on which said lot has a
frontage.
Section 41: It is hereby adjudged and declared that existing
conditions are such that this Ordinance is necessary for the imm-
ediate preservation of the public peace, health and safety; and
an emergency hereby is declared to exist and this Ordinance shall
take effect and be in full force and effect from and after its
date of passage.