Loading...
HomeMy WebLinkAboutResolution 356 - Bluebird Heights Tent. Plan PLANNING COMMISSION RESOLUTION NO. ~5~ A RESOLUTION GRANTING APPROVAL OF A TENTATIVE PLAN FOR BLUEBIRD HEIGHTS SUBDIVISION (Applicant: C. David 'reel) (37 2W 2BC Tax Lnts ].101 and 1500} BE TT RESOLVED BY THE PLANNING COMMISSION OF THE CITY OF CENTRAL POINT, OREGON, AS FOLLOWS: Section 1. Nature of Application. This is an application for approval of a tentative plan for a 17-lnt subdivision in an R-3 district of Central Point, Oregon. The Planning Commission reviewed the application and tentative plan at a duly-noticed public hearing on July 2, 1996. Secta~on 2. Apprroval Criteria. The criteria far approval of this subdivision application are found in CPMC Title 16, relating to tentative plans and subdivisions, and in Title 17, relating to zoning and lot sizes. Section 3. Findings and Conclusions. The Planning Commission finds and determines as follows: A. Tentative Plan Requirements. The application and tentative plan herein are in the correct form and contain all of the information recruited for the same under CPMC Chapter 16.10. B. Area and Width of Lots. The subdivision lots all meet the R-3 district lot size requirements, except lot 2, which is a flag lot, and must be increased slightly in size to meet the minimum 12,000 square feet requirement for flag lots, excluding the access. C. Blocks and Streets. The tentative plan proposal for the layout and dimensions of streets and blocks is in compliance with the requirements of CPMC Chapter 16.20 regarding streets and CPMC Chapter 16.24 regarding blacks. Section 4 Conditional Approval. The application for tentative plan approval for the within subdivision is hereby approved, subject to the following conditions, imposed under authority of CPMC 16.10.090. Conditions 1. Lnt 2 shall be reconfigured to be 12,000 square feet minimum excluding access. 1 - PLANNING COMMISSION RESOLUTION NO. 3SCo (071696] 2. The applicant shall submit to the City's Public Works Department plans and specifications for all improvements proposed for construction or modification within the City's rights-of-way or easements. All construction shall conform to the City's Standard Specifications and Uniform Standard Details for Public Works Construction and such other special specifications herein. No construction shall commence until the Public Warks Department has reviewed, approved, and issued a permit for the proposed improvements. The developer shall pay for all costs associated with the design and installation of the improvements specified on these plans. 3. Prior to final approval of the project, the developer's engineer or surveyor shall provide the Public Works Department with a digital drawing of the final plat property boundaries in an AutoCadd compatible format. 4. The public works improvements for the development shall include the widening of the east side of North Tenth Street to a 22-foot half section from centerline to the east face of curb. The widening shall extend from the existing 22-foot half street section approximately 35 feet north of the project to approximately 20~ feet south of the southerly project boundary. 5. The construction drawings for this tentative plan shall include a Street Lighting Plan and a Traffic Control Plan in accordance with the requirements of the City of Central Point Public Works Department. The construction drawings shall include clear vision areas designed to meet the City's Public Warks Standards. 6. The City's engineer shall, at the cost of the developer, evaluate the strength of the native soils and determine the street section designs in accordance with the Public Works Department Design Standards. 7. The developer shall construct an adequately sized storm drainage system to provide for runoff onto the subdivision property and from each lot. Prior to construction plan approval of the improvements for this tentative plan, the developer's engineer sha11 provide a complete set of drainage calculations for sizing the storm drainage system. The engineer shall use the rainfall/intensity curve obtained from the Public Works Department for hydrology calculations. Curb and gutter sections sha11 not exceed 350 feet before entering a catch basin or cub inlet. 8. Ali sewerage system design, construction and testing shall conform to the standards and guidelines of the Oregon DEQ, 1990 APWA Standards, Oregon Chapter, and the City of Central Point Standards. The City wi11, upon completion of plan review 2 - PLANNING COMMISSION RESOLUTION N0. ~_ (071696) and approval, submit the plans to the Oregon DEQ for sewer system design approval prior to issuance of a construction permit. The developer's engineer shall provide DEQ and the City with test reports and certification of the sewer system construction prior to final acceptance by the City. 9. The construction shall comply with Oregon Health Division requirements for Backflow prevention. 14. The developer's engineer shall design the water system to provide a minimum fire flow in conformance with the requirements of City's Fire Chief. 11. The construction drawings shall indicate type, size and location of water mains and fire hydrants in accordance with the City's Public Works Standards and the recommendation of the City's Fire Chief. 12. Developer shall provide a grading/paving plan with the construction drawing submittal to the Public Works Department. A11 structures shall have roof drains, area drains, and crawl spaces with positive drainage away from the structure and drain lines connected to a curb drain, or an approved storm sewer. The developer shall provide the necessary ~~rough" lot grading to assure that all lots will drain properly. The developer shall submit a grading plan with the construction drawings, and perform such grading and drainage improvements which satisfies this drainage condition, leaving only minor grading required for each lot during house construction. 13. The construction drawings and final plat shall show all right-of-way and easement boundaries associated with the project. Passed by the Planning Commission and signed b me in authentication of its passage this ~ day of , 1996. Planning Commission Chairman ATTEST: City Repres nt ive Approved by me this ~-- day of , 1996. ~~~ Planning Commission Chairman 3 - PLANNING COMMISSION RESOLUTION NO. ~(~ (071695)