PLANNING COMMISSION RESOLUTION NO. 427
A RESOLUTION APPROVING A "I'I~N'I'ATIVI~ PAR"I'ITION
AND SI`I'E PLAN REVIEW
( 37 2W 02 TAX LOTS 140, 1200, 1300 & 1400)
( Applicant: Mingus Creek Plaza)
Recitals
The applicants are proposing the development of a community shopping center with a n~zaj or retail
grocery store as the anchor and seven other retail con~znercial uses inclzzding a gas station and
restaurant as co-tenants.
2. The applicants are also requesting a zxzizaor partition to separate the grocery store, its parking area
and an associated gas station (7.2 acres) from a second parcel (8.1 acres} with six other retail uses
and a third parcel {4.9 acres} planned for ahospitality/zxzotel center.
3 . On July 7,1998, the Central Paint Planning Commission conducted aduly-noticed public heating
on the application, at which time it reviewed the City staff reports and heard testimony and
comments on the application.
Now, therefore;
BE IT RESOLVED BY THE PLANNING COMMISSION OF THE CITY OF CENTRAL POINT,
OREGON, AS FOLLOWS:
Section 1. Approval Critezia. The following chapters of the Central Point Municipal Code appy
to this application:
A. CPMC 10.10.010 et seq. Tentative Plans
B. CPMC 17.44.010 et seq. C-4, Tourist and Office Professional District
C. CPMC 17.60.010 et seq. General Regulations
D. CPMC 17.04.010 et seq. Off Street Paz•king
E. CPMC 17.72.010 et seq. Site Plan, Landscaping and Construction Plan Approval
Section 2. Finding and Conclusions. The Planning Commission finds and determines as follows:
A. Ten~tive Plan for a Land Partition Requirements. The application and tentative plan are
in the correct form and contain all of the information required by CPMC Chapter 16.10.
1 -Planning Commission Resolution No. 427 {07107198)
F3. ;~t~ til~,~i l~'TCiti~ofLot. C1'MC` 17.28.t)~~1,'st~~ialisl,cs nlini,Tttn~, u,~c~,. ~,ai{Iti~un~1 F;~`~:vSs
recl~~ir~n~cnt ti~rthe ~.~`-4~'1"cr~.~ri5t ~,n~i (,)11i~~~~ ~l'rt,i~•~;;i~7,~,1? flist~i~~t.
Parcel 1:
Parcel 2:
7.2 ~,c~res
8.1 ttt,L
1.~1 a; res
S~eti.c~~i 3. Conchtior~al ~~prc~val. `hl7c apPlicatirn f~~r Site t~lan and ~~T'cr,i~,ti~.~c N1 i n~~r Land
Partiti~:~n 1,;~,~~ i,-~ is hereby ~~~rrc~v~ci, s~~bject tc~ t?~c cc~,~<f itic~i,~ ~~~~ 1 <]r :~~ an 1~~hibit °°tl,', ~;i t< <ci~~ ~ i ~,~r;~tt~ ~nc3
by reference incoa°pc~rated 1~crein~ in~l~os~:~1 u,~;i~ r a~~,=hcrrity ~.~I'CP~C 16.36.
Passed. by tli~ f'i~u~aninf; Cc~znmissic~n anal ~r;-'.nei~l by me in authenticaticaa~ c~f'its i, i~~a~, c~ this
'` ~ ~'` day c~i~__ 1998.
~-
ChUC;~ Piiai~~_i
Pla?~,~in`~, C;omznssian Chairman
~TTF,ST:
,gib ~r
~ ___,m..e.,..v_.-.~.,.~_.....~~.._~..___~,
Cit~ l:e~a~.s~ibta.~,,.,
:
ApPrc~ved by me this :' `~ day ai'___.. -~~_._, 1998.
`7
Chuc1 I'i I ~:~~?
Planning, Commission Chairman.
2 - Planning Commission 12esolution No. 427 (071fl7/98)
EXI~III3IT ~~
PLANNING DEPARTMENT RECOMMENllI~.)]) CONI)ITIQNS 4I~ AI'l'ROVAL
`l'he applicarltJproperty owner shall submit subsequent building elevatiorls to
the Planning Cor11r11issiorl as they l~ecotrte availalile for architectural review.
2. The approval of the Tentative Plan shall expire ir1 one year or1 J~rly 7, 1999 unless art
application for final plat or extension has been received by the City. Reciprocal
Easer11er1t Agreements shall be obtained and recorded prior to or ir1 canjurlctiarl with
the recording of a final plat,
3. The project must comply with all applicable local, state and federal regulatrons
including, but not limited to, any requirements of the Division of State Lands for
working within a water way.
4. The tentative and final plats shall depict utility easements requested by the City,
BCVSA and WP Natural Gas. Any changes to utility layout including fire hydrants
shall require subsequent approval by the respective service provider.
5. The applicant/praperty owner shall be responsible for the payment andlor
construction of recommended transportatiorl improvements including, but not limited
to, a traffic signal at the Freeman/Oak Street intersection; raised medians as
determined by the City Public Works Department; a transit shelter and four way stop
signage at the intersection of Freeman and Hopkins Roads.
6. The applicant/property owner shall submit final parking, landscaping, lighting and
sign plans to the Planning, Public Works and Building Departments for approval
prior to obtaining any building permits.
CITY OF CENTRAL POINT
DEPARTMENT OF PUBLIC WORKS
STAFF REPORT
for
CENTRAL POINT TOWNS CENTER
PW#98033
Date:
Applican#;
Project:
Location
Legal:
Zoning:
Area:
Units:
Plans:
Report By:
Purpose
July 6, 1998
Central Point Towne Center, L.L.C., P.O. Box 8271, Medford, Oregon 97504
Agent: Charles Martinez, 744 Cardley Avenue, Suite 100 Medford, Oregon 97504-6124
Owners: Rowe (Trustee} (1100}; Lamb (1200}; Five Star Properties, Wes#, L.L.C. {1300};
and Korner {1400}
Central Point Towne Center
East of Intersection of Freeman Road and Oak Street
T37S, R2W, Section 2 Tax Lots 1100, 1200, 1300, 1400
C-4, Tourist and Office Professional District
20.2 Acres.
3 Parcels:
Parcel 1:7'.2 acres far grocery Store, gas station, and parking
Parcel 2: $.1 acres #or six other retail buildings with parking
Parcel 3: 4.9 acres for hospitality/motel center with parking
1 `tentative plat" illustrating division of tax lots into 3 parcels prepared by Noffbuhr &
Assoc., amended Jufy 2, 9998; and Site Plan - 16, drawing 5-101, dated July 2, 3998
prepared by Abeloe & Associates, A.I.A.
Lee N. Brennan, Public Works Director
Provide information to the Planning Commission and Applicant (hereinafter referred to as "Developer")
regarding City Public Works Department (PWD} standards, requirements, and conditions to be included
in the design and development of the proposed industrial facility. Gather information from the
Developer/Engineer regarding the proposed development.
Special Requirements
Existln Infrastructure: The Developer shall demonstrate that all connections to existing
infrastructure (i.e. streets; water, sanitary sewer, storm drain systems; natural drainage systems;
etc.,} will not interfere with or provide far the degradation of the existing effective level of service
or operation of the infrastructure facilities, and chat the existing infrastructure facilities have
either adequate capacities to accommodate the flows andlor demands imposed on the existing
infrastructure as the result of the connection of the proposed development's infrastructure, or wil'
be improved by and at the expense of the Developer to accommodate the additional flows
andlor demands; while maintaining or improving the existing lave! of service of the affected
facility, as approved by (as applicable}, the regulatory agency, utility owner, andlor property
owner involved.
2. Master Plans: In association with City PWD staff, the Developer shall prepare master plans for
the storm drain collection, retention, and conveyance system, the sanitary sewer collection and
conveyance system, and the water distribution system for the subject tax lots and the areas to
the north and south of the proposed development. The master plans should take into account
the flows or demands of the proposed development, any future development on neighboring
portions of the subject tax lot, on neighboring properties, and any areas deemed by the City that
~rulral 1'nnrl 1 r~nvcc~ (c'rtlc'r'
I'll"f) ~'1u//7lryrnrr
.11crr'- 1?9~ti
f'u~r° ,
will need to connect-into the proposed development's or existing neighboring infrastructure. The
prepared master plans should take into account any previous master plans that have been
prepared and approved by the City and Jackson County.
3. Rrghts-of--Way arrd.Easemenfs: Provide dedication for expansion of the righf-of-way along
Freeman Road to accommodate necessary improvements to Freeman Road to accommodate
traffic and turning movements associated with shopping center. For the traffic lanes proposed
on the site plan, this would require right-of-way widths ranging from 68 feet to 82 feet in width.
Since the western side of Freeman Road has existing residential development, this would likely
necessitate obtaining all the remaining required right-of-way width from the eastern side of
Freeman; thus requiring additional righf-of-way dedication ranging from 8 to 22 feet from the
proposed development. Additional right-of-way may need to be obtained from tax lots 1500 and
1600 to construct a northbound deceleration lane.
The Developer shall provide suitable and acceptable easements for any public works
infrastructure loco#ed outside the public rights-of-way. A separate 10-foot minimum width public
utilities easement (P.U.E.) should also be required for utility installation outside the Freeman
Road right-of-way along the property's exterior frontage with Freeman Road, and potentially with
frontage on Interstate 5.
Ail construction plans and as-built drawings shall accurately portray (both horizontally and
vertically) utility line and appurtenance locations and the locations of any existing and new
easements on the proposed development..
4. Traffic Study: A draft #ransparta#ian impact study for the proposed development, prepared by
Ki#telson & Associates, Inc., dated June 17, 1998, has been submitted to the City. The draft
traffic study analyzed the year 2000 projected traffic flows and intersection levels of service at
the intersections most likely to be impacted from this development; namely:
Freeman and Hopkins Roads
Freeman Road and East Pine Street
Freeman Road and Oak Street.
As summarized in tables 3 and 5, and in the Findings section of the report {beginning on
page 20), two of the three affected intersections would be greatly affected (Freeman and
Hopkins Road, and Freeman Road and Oak Street): the level of service of these intersections
would drop to unacceptable levels, based on the estimated traffic flows.
The proposed solution for the intersection of Freeman and Hopkins Roads would be to install a
4-way stop sign. This would result in an estimated level of service (LOS) rating decline from "B"
without development to LOS "C" with the development, which meets the City's current minimum
LOS requirements.
The proposed solution for the intersection of Freeman Road and Oak Street is for the installation
of a traffic signal (separate turn lane movements) at this intersection. A signal warrant study
was performed, and it was determined that based on the projected traffic flows and turning
movement at this intersection that a traffic signal for this intersection is warranted.
Central Point Tox~ne Center
P#'D Staff Report
A4nv l7, 1998
Page 3
City PWD staff concur with the proposed improvements to these intersections, and
5. Landscape Buffers: Provide for City PWD and planning department and JC Roads approved
landscaped buffers (including suitable landscaping and meandering sidewalks) along the
applicable portions of 1=reeman Road.
6. Improvements fo Freeman Road: Freeman Road along the frontage of the subject
development is a rural road that does not meet current City or County urban standards. The
road will need to be improved, as a minimum, to meet City standards and the traffic flows (both
vehicular and pedestrian) created as a result of the proposed development. Since the trafFic
flows created as the result of this development affect bath the southbound and northbound
directions of Freeman Road, It as the Clty PWD's recommendation that the Developer be
responsible for, as a minimum, all necessary improvements to Freeman Road along the
proposed development's property frontage with Freeman Road, and any applicable taper or end
sections. The improvements include, but are not limited to, street section, curbs, gutters,
sidewalks, bikeways, street lighting, storm drainage, landscape buffers, and traffic control and
delineation (including appropriate traffic signals at the intersection of Freeman Road and Oak
Street), which shat! be coordinated and approved by the JC Roads and the City PWD, and
designed and constructed at the expense of the Developer as part of the proposed
development.
7. Erosion Confrol Plan: if applicable, a suitable erosion control plan must be prepared and
submitted to the Oregon Department of Environmental Quality (DEQ) for the construction of any
improvements associated with this development. The construction plans associated with this
development will not be approved by the City PWD until the City PWD receives a copy of the
written approval of the erosion control plan by the DEQ.
8. Storm Drainage System: The storm drain system shall be designed to accommodate the
storm water run-off from and run-on onto the proposed development (either surface run-on or
culvert or creek/ditch conveyance); any future development on adjacent properties; conveyed
storm drainage or surface water flow, and any flows from areas deemed by the City that will
need to connect-into the proposed development's SD System. It appears #hat the majority of
surface water flows from the properties south and possibly north of the subject tax lots drain
across the subject tax lots. The proposed storm drainage system will need to be designed to
accommodate these existing "run-on" flows. However, the City is requesting that the developer
design the storm drain conveyance system to accommodate projected post-development flows
from these properties. City would propose reimbursement to the Developer far up-sizing the
applicable up-sized portion(s) of the storm water conveyance system to accommodate the future
development on these neighboring properties, as applicable. The City is currently developing a
schedule for the cost differences for up-sizing storm drain pipe and manholes. Once the cost
table is developed, the cost differences will be multiplied against the lineal feet of storm drain
pipe for the various pipe up-sizing, and the number of manholes up-sized, to determine the total
reimbursemen# that would be due the Developer. Once the amount of the reimbursement is
determined, it is proposed that the City would enter into an agreement with the Developer that
calls for payment of the determined reimbursemen# amount (which would likely be designated as
the "Towne Center storm drainage project fee") as it is collected from the developers of the
affected properties.
C°ertPr'al f'otrrr 7~nu~ne C'errrer
afar l', f 99tY
f'a~e -!
9. off-Site Storm Drainage Infrastructure: For any storm drainage infrastructure constructed or
improved outside the City's rights-of-way or easements for drainage of surface waters from the
subject development, the Developer shall provide a suitable document or documents which
contain approvals for the implementation of such connection andlar improvements and which
describe:
^ Who is responsible for the operation, maintenance, and repair of the infrastructure
facilities to maintain the original design parameters associated with the infras#ructure. If
the City is to operate and maintain the infrastructure, the applicable funding mechanism
that will be created (i.e local improvement district) far the associated City expenditures;
^ How will access be afforded and maintained indefinitely to maintain and repair the
infrastructure facilities;
^ That an easement or other suitable conveyance document has been granted, as
necessary, to provide suitable access an private property for the inspection,
maintenance, and repair work to be performed on the infrastructure facilities. The
easement shall include a statement which allows access by City personnel for inspection
and maintenance purposes; and
10. Creek Sefback Requirements: Creek setback requirements of CPMC 17.50.090 E. may affect
some of the proposed developments strucutres {i.e "Outdoor Dining" area". As applicable,
should require maintenance access easement and 20-foot maintenance access road as
indicated in the this creek setback requirement of the City's municipal code.
11. Wafer Distri,bufion 5ysfem: The water system should be of "reinforced loop" design: a
minimum of two connections will need to be made to the City's distribution system {12-inch
water line) on Freeman Road. This distribution line, according to recent Fire District 3 tests,
should be able to accomodate a maximum fire demand flow rate of 4,000 gpm. if additional fire
flaw demands will be required by the development, then the Developer wilt be resonsible for up-
sizing the existing lines to obtain the required flows, as applicable.
12. Flood Study of Mingus Creek: The proposed development places improvements and
structures within ar alters the 100-year floodzone associated with Mingus Creek. The Developer
should be required to have a 100-year flood study analysis performed. The flood study must
provide findings which indicate what affect does the placement of the proposed improvements
and struc#ures have on the base flood elevation and floodzone boundary, and what affects will
the modification of the floodplain eleva#ion and floodzone boundary have an the existing facilities
and properties surrounding the proposed development. The Developer's engineer shall
determine the existing base flood flow rates and the base flood elevation contours; and illustrate
the existing boundaries of the floodplain and floodway fora 100-year "base flood" storm event
associated with Mingus Creek through the affected properties. The construction drawings shall
indicate the revised base flood elevation contours and boundaries of the floodplain and floodway
expected to occur following the completion of any development within the identified floodzone
(also referred to as the "Area of Special Flood Hazard"), including any affected upgradient
areas. The information determined in this study wi11 also be used to determine minimum finished
floor elevations for any structures that will be placed within the area of special flood hazard.
Central Point Towne Center
P6f'D Staff Report
May z ~, 19 s8
Page S
General
All construction of public improvements shall conform to the City's PWD Standards, the
conditions approved and stipulated by the Planning Commission, and other special
specifications, details, standards, andlor upgrades as may be approved by the City
Administrator or his designee prior to the approval of the construction plans for the proposed
development. During construe#ion, changes proposed by the Developer shall be submitted in
writing by the Developer's engineer to the City PWD far approval prior to implementation.
2. Developer shall provide copies of any permits, variances, approvals, and conditions as may be
required by other agencies, including, but not limited to, the Oregon Department of Fish and
Wildlife {DF'W}, Oregon Department of Environmental Quality (DEQ}, Oregon Division of State
Lands {DSL}, U.S. Army Corps of Engineers {ACOE), affected irrigation districts, and JC Roads.
3. Prior to approval and acceptance of the project, the Developer's engineer or surveyor shall
provide the Public Works Department with "as-built" drawings. If #easible, the Developer's
engineer ar surveyor should provide the drawings in both a "hard copy" form (produced on
Myiar~) and in a "digital" format compatible with AutoCAC~, or other farm as approved by the
City PWD.
As-built drawings are to be provided to the City which provide "red-line" changes to final
approved construction plans that identify the locations and or elevations (as appropriate} of
actual installed items, including, but not limited to, invert, inlet, and rim or lip elevations; spot
elevations identified on drawings; road alignment; water lines, valves, and fire hydrants; water
and sewer lateral stationing; modifications to street section; manhole and curb inlet locations;
street light locations; o#her below grade utility line locations and depths; etc. Provide a "red-
line" hard copy (on Mylar'~), or an approved alternative format, of construction drawings, and if
#easible, an acceptable AutoCAD~ compatible drawing electronic file to the City at completion of
construction and prior to acceptance of public in#rastructure facilities completed as part of the
proposed development, or as otherwise approved by the City Administrator or his designee.
4. All elevations used on the construction plans, on temporary benchmarks, and on the permanent
benchmark shall be tied into an established City approved benchmark and be so noted on the
plans. At least two permanent benchmarks shall be provided for the proposed development, the
locations of which shall be as jointly determined by the City PWD and the Developer.
5. If applicable, all existing concrete, pipe, building materials, structures, clear and grub materials,
and ether deleterious materials shall be removed from the site and either recycled or properly
disposed of in accordance with the requirements of the DEQ.
S. Easements far City in#rastructure (i.e. sanitary sewer, water, and storm drain [if applicable]}
should be a minimum of 15-feet wide, and should not spit lot lines. Easements for public storm
drainage, sanitary sewer, and water lines should be dedicated to the City and not just a P.U.E.
Centerline of buried infrastructure shall be aligned a minimum of five (5) feet from the edge of
the easement. If two or more City owned utilities are located within an easement, then a
minimum of 20-foot width should be required. Easement dedications in final deeds or CC&Rs
need a statement which should clearly indicate that easements must be maintained with
suitable, driveable vehicular access to City public infrastructure facilities, as determined by the
City PWD.
<~cx(ra! Pvrrr~ I'ms~uc' C~cater~
!'iF7J.Sraff Rc~ixrr!
;11cn• 3°. 199cY
/'atc~
7. Prior to the City PWD final approval of the construction plans for the proposed improvements,
the following should be submitted:
^ A copy of written approval from l=ire District 3 of the final street and driveway layout, site
access, fire hydrant placement, and water system improvement plans for the proposed
development.
^ The plans relating to the sanitary sewers should be approved in writing by BCVSA, and
the appropriate signature blocks should be completed on the plans.
^ A copy of written approval from JC Roads regarding Freeman Road improvements {as
applicable} and driveway connections to Freeman Road.
8. Field verify all existing infrastructure elevations and locations {i.e. pipe inverts, curb elevations,
top of banks, ditchlchannel inverts, street elevations, etc.), to which the proposed development's
infrastructure will connect into existing improvements, prior to final construction plan design and
submit#al for final approval.
9. Overhead power lines. If applicable, coordinate efforts with Pacific Power and Light, US West,
and TCI Cable, to convert any overhead electrical power, telephone, or cable facilities within the
proposed development to underground facilities, prior to the acceptance by the City PWD of the
public improvements associated with the proposed development. All agreements and costs
associated with the conversion of these facilities from overhead to underground facilities, shall
be by and between the utility owners and the Developer.
10. The accurate locations of any existing underground and above ground public infrastructure, and
the location of the associated easements with these facilities, shall be accurately portrayed {both
horizontally and vertically) on the construction plans and as-built drawings.
11. The Developer's engineer ar surveyor shall provide to the Public Works Department a drawing
of the recorded Final Plat map reproduced on Mylat~ and in an acceptable electronic form in
AutoCAD® format. The Final Plat shall be tied to a Segal Government corner and the State Plane
Coordinate System. Ths Final Plat shall either reflect or be later modified to reflect any
applicable "red-line" changes no#ed in the construction "as-b~ilts", at the discretion of the City
Administrator or his designee.
StreetslTraffic
Existing Improvements - Freeman Road -Secondary Arterial. Current ROW 60' wide,
varying street width. Right-of Way required: varying width
Jurisdiction -Jackson County.
Construction drawings for #his Tentative Plan shall include a Street Lighting Plan in accordance
with the requirements of the City PWD or as otherwise approved by the City Administrator or his
designee. The construction drawings shall include clear vision areas designed to meet the
City's PWD Standards.
2. The Developer's engineer shall, at the cost of the Developer, evaluate the strength of the native
soils and determine the private drivewaylstreet and parking lot section designs to accommodate
C'c~rlral I'oirrl 7~ois•rte Center
f'14`U Sru/f Kr~pa•1
Mao ?-. 1998
Pa~c -
the expected loads (including fire equipment and delivery trucks) to be traveled on these
driveways. If a public street, then the City will design the required street section.
Storm Drainage, Irrigation Improvements
Existing Improvements - Mingus Creek flows south to north across the western portion of
proposed development.
Rogue River Valley Irrigation District potentially controls irrigation
rights within the project area including conveyance of water in
Mingus Creek.
Developer's engineer shall develop a facility plan for the storm drain collection, retention, and
conveyance system (SD System) which provides for storm water run-off from and run-on onto
the proposed development (ei#her surface run-on or culvert ar creek/ditch conveyance), any
existing or future development on adjacent properties, conveyed storm drainage, or surface
water flow (i.e. Mingus Creek), and any areas deemed by the City that will need to connect-into
the proposed development's SD System.
2. Developer's engineer shall determine how SD system will work during 10-year and 100 year
flood events associated with Mingus Creek. Identify the HGl_ in Mingus Creek during 10-and
'100-year storm event, and what affect it will have on the proposed outlets and storm drain
system. System should be designed to adequately drain 10-year storm without surcharging ar
should be provided with adequate storage to prevent surcharging; and be designed to prevent
backflow of water from Mingus Creek up into SD system during storm events.
3. During the design of the SD system, the Developer's engineer shall consider the effect of the
proposed improvements and structures with regard to the 100-year base flood event floodway
and ffoadplain of Mingus Creek. The design of the storm drain collection and conveyance
system (SD System) should provide for storm water run-off from and run-on onto the proposed
development {either surface run-on or culvert or creeklditch conveyance}; the Developer shall
demonstrate that the storm water flows from the completion of the proposed development {and
at any time prior to completion of development} do not exceed predevelopment flows into
Mingus Creek; or that allowances or provisions have been made (and approval of the applicable
properties owners and regulatory agencies has been obtained), which accommodate any
additional flow which exceed predevelopment flows. The Developer and the City PWD shall
agree on the applicable run-off coefficients, curve numbers, retardance, etc., to be used in the
engineering calculations.
4. Developer's engineer shall provide a site drainage plan with the facilities being designed, at a
minimum, to accommodate a 1 D year storm event. The SD system must be designed to
adequately drain the 10-year storm event without surcharging or must be provided with
adequate storage to prevent surcharging; and be designed #a not impact existing public storm
drainage facilities. Catch basins and area drains shall be designed for nn-site sediment and
petroleum hydrocarbon retention. The private storm drain system shall be designed to directly
connect to the public storm drain system, and shall not be designed to discharge to the street
surfaces. Surface drainage from the fuel storage and dispensing facilities shall not be directly
connected to the storm drainage system without prior approval by the DEQ and City PWD.
C•e+:f+~n! Pol+rt Tax°rae C'ente+'
Pi#'I3 Staff Kepart
htati- 2?. 1998
r~«~>~> s
5. Roof drains and underdrains shall not be directly connected to public storm drain lines, and shall
drain to the on-site private storm drain system.
6. As applicable, any discharge points of the storm water facilities steal! be designed to provide an
aesthetically pleasing, useful, and low maintenance facility, that are designed to mitigate
erosion, damage, or loss during a 100 year storm event; and that mitigate the "attractive
nuisance" hazards associated with these types of facilities.
7. Prior #o City PWD construction plan review, the Developer shall provide the City PWD with a
complete set of hydrologic and hydraulic calculations and profile plots for sizing the SD system,
which shall incorporate the use of the City PWD's rainfalllintensity curve, and City approved run-
off coef€icients, curve numbers, retardance, pipe roughness coefficients, etc., that are used in
the engineering calculations.
8. Public storm drain pipe materials shall be PVC, HDPE, or reinforced concrete, with water-tight
joints. Provide concrete orsand-cement slurry encasement where required in areas of minimum
cover.
9. if inlets/catch basins are to exceed ~4.5 feet in depth from the lip of the inlet, then the inlets and
ca#ch basins shall be designed to afford suitable "man" entry into the inlets/catch basin far
maintenance/cleaning purposes.
10. Developer's engineer shall provide hydrology and hydraulic calculations and flow line plots for
private and public storm drains. Plot HGL on profile or provide a separate profile drawing that
indicates the HGL on the profile. Pipes should maintain cleaning velocity (minimum 2.0 feet per
second} and have adequate capacities without surcharging during the design storm.
11. The Developer may wish to incorporate the use of a perforated SD system. If so, then the
perforated storm drain system shall be designed to have adequate capacities to:
^ Convey the collected groundwater and storm water with the minimum cleaning velocities
and wi#hout surcharging the collection and conveyance piping; and
Cl Minimize silts, sands, gravels, and fines migration from the native soils into the SD
system.
The plot#ed HGL shall include both the groundwater infiltration, and the storm water run-off and
run-on inflows into the SD system.
12. In the public storm drain system, main#ain a minimum 0.2-foot drop between inlet and outlet pipe
inverts in manholes and curb inlets, unless flow-through velocities during the design storm event
exceed 3.0 feet per second {fps). If flow velocities exceed 3.0 fps and the inlet pipe is in
relatively direct (i.e. '180 ~ 5 degree) horizontal alignment with the outlet pipe, then as a
minimum the pipe slope shall be maintained through the base of the manhole or curb inlet. If
flow velocities exceed 3.0 fps, and there is other than relatively direct horizontal alignment
between the inlet and outlet pipes, then a minimum of a 0.1-foot drop between inlet and outlet
pipe inverts in manholes or curb inlet must be maintained. A bottom channel shall be formed in
the manhole ar curb inlet base to mitigate #ransitional losses and enhance flow through the
manhole or curb inlet.
C~entra! Point loirnc' Ccritcr
f ri'f? Staff I2efu~rt
rilav l a, 1994
Pale 9
13. Sheet flow surface drainage from the property onto the public rights-of-way or onto neighboring
properties is unacceptable.
1~. Plans which propose to include the discharge to Mingus Creek and any construction or
modification within the floodway of Mingus Creek or in the road ditches, shall be in compliance
with DS!-, ACOEr, ODFW, DEQ, JC Roads, andlor City PWD (as applicable} guidelines and
requirements and any applicable conditions and ar approvals, of these regulatory agencies.
Sanitary Sewer
All sanitary sewer collection and conveyance system (SS System) design, construction and
testing shall conform to the standards and guidelines of the Oregon DFQ, 1990 APWA
Standards, Oregon Chapter, Bear Creek Valley Sanitary Authority (BCVSA), and the City PWD
Standards, where applicable.
2. The construction plans and the as-built drawings shall identify lateral stationing for construction
of sewer laterals.
3. The City upon completion of initial construction plan review and preliminary approval, will
forward the plans to BCVSA for completion of the review process. Upon completion of the
review by BCVSA, completion of final revisions to the plans by the Developer's engineer, and
following the final approval and signature on the construction plans by BCVSA, the Public Works
Director will approve the plans in final form.
4. All testing and video inspection of lines and manholes shall be done in accordance with BCVSA
requirements, at Developer's expense. The Developer shall provide BCVSA and the City with
test reports, TV reports and certification a# the sewer system construction prior to final
acceptance.
Water System
The water system shall be designed to provide the required fire flow demand capacities far the
proposed facility, which meet Fire District 3 requirements. Maximum spacing of fire hydrants
shall be 300 feet. The water system shall be of reinforced flow ("looped") design. Water service
lateral connection stationing and size shall be provided on construction plans and as-built
drawings.
2. Developer shall comply with Oregon Health Division (OHD) and Ci#y requirements for backflow
prevention.
Site work, Grading, and Utility Plans
Grading plans should have originallexisting grades and final grades plotted on the plan.
Typically, existing grade contour lines are dashed and screened back, and final grade contour
lines are overlaid on top of the existing grades and are in a heavier line width and solid. Contour
lines should be labeled with elevations.
2. All structures shall have roof drains, area drains, andlor crawl spaces with positive drainage
away frog the building.
Centro! Point 7ouvie Center
PF3'D Staff IZepor't
Afay 1 ~, 1998
Page I Q
3. Provide City with a utility plan approved by each utility company which reflects al[ utility line
locations, crossings, transformer locations, valves, etc.
4. Utility locations must be accurately included on the as-built drawings, or as a separate set of
drawings attached to the as-built drawings.
Rights of Waysl~asements
If applicable, Developer shall provide a Statement of Water Rights (on a City approved form), for
any affected properties. far properties determined to have water rights, the developer will
coordinate with the State Watermaster the re-allocation of any waters attached to [ands no
longer irrigable as a result of the proposed development.