Loading...
HomeMy WebLinkAboutResolution 494 - Cavin and Smith Partition~ (~` ~~.: PLANNING COMMISSION RESOLU'I'lON NO. 494 A RESOLUTION GRANTING TEN'I"ATIVE PLAN APPROVAL FOR A LAND PARTITION (Applicant (s) : Dona]d A. Cavin and Taae D. Smit11 } ( 37 2W02CB, Tax Lot 3700 ) Recitals l . Applicant(s) has/have submitted ail applications for tentative plan approval for a land partition on a .3S -acre parcel, located in the R-2, Residential Two-Family District in the City of Central Point, Oregon. 2. On August 1, 2000, the Central Point Planning Con3missionconducted aduly-noticed public hearing oxz the application, at which time it reviewed the City staff z-eports and heard testimony and comments on the application. Now, therefore; BE IT RESOLVED BY THE PLANNING COMMISSION OF THE CITY OF CENTRAL POINT, OREGON, AS FOLLOWS: Section 1. Approval Criteria. The requirements for approval of Iand partitions and tentative plans are set faith in CPMC Title 16 and 17, relating to informational requirements, zoning, lot din-zension, access, and similar requirements. Section 2. Finding„and Conclusions. The Planning Commission finds and determines as follows: A. Tentative Plan Requirements. The application and tentative plan are in the correct fozn1 and contain all of the information required by CPMC 16.10. B. Az-ea and Width of Lot. This partitioning in an R-2 zone would create the following parcels: Parcel l: Approximately $,800 square feet; Parcel 2: Approximately 6,600 square feet; Parcels I and 2 n~zeet the minimum area ( 7,000 square feet for interior Iots and 6,000 square feet for corner Iots} and width {60 feet for interior Iots and 70 feet for corner lots} requirements for lots in the R-2 zone as set forth in CPMC 17.24.040-060, and such parcels zxzeet the general requirements for lots contained in CPMC 16.24.050. Planning Commission f2esolution No. ~~ {051998 } ~~~ Section 3. Conditio~lal Approval. The application for te~ltativc p]an foE• land partition herein is hereby approved, s~rbjcct to the conditions set forth on Exhibit "A", "B", and "C" attached hereto by reference incorporated herein, imposed cinder a~rthority of CPMC Chapter 16.36. Passed by the Planning Com~i~issian artd signed by me in a~rthentication of its passage this ~~ ~ day of ~ ~ ~-~ ~ , 2000. Planning Coznzx~ission Chair ~` ~ day of /h~ ~ ~ S ~' , 2000. Planning Commission Chair Planning Commission Resolution No. _420 (051998 ) ATTEST: --` ....~ U., ~.~. a.w~ R 6.r ~ !kr R . . ~,~x~~~~ ~~ ~...~.. Yr+.+4 st s..h R..f s rv~c ac t r~ wcsruw ~c~srw s.a... c~...y~ o~v.. ~ br.a~ iw* 4 rd I r{.d f! o,~.ar,.,.rar~ ~.+.r ~._,.~.~,.,._.r._~. ~...~ ~« ~.... ««., L hKwi [s 1 ~1n • (4M R L ~~ ~W 11rwlq 1 i.~+~M R ~~ t~wrl4~rfi.f4~1~ H l.wK ~.. _ . f ~~4 s~~+h T+' ~ 1~w~ wr Qfwwr~ ~ s..r. ~. ~y+. • Mw~+w Fwnr hr -f- Ilr.w~ ~ f...w ~ \ ~- ~ / hi ~~` `~ ~,. ~y 4\ ``\ \?~ <' \ `` \ ~4t it \A ~ .~ `~ ~ /,. \ \ ~., . ,~ ;,. ~,. ~. fi.t~d L Carr. ~l.l. 1~Of D~tV Iar -LeJf.N, Or. l~7Ff Jt1dSS-{iK Tri i1td75~t7A tN+~T T~~ if irsi t OrYr, ~~ t.dnrM 1/r L.rrgRl4lfl~ ~r....r Y W..+r r AwW !'~~ - W ~ Ir" - r 7~x i..e 7'IaS mN7C11. a ~+~~d noresccoKAt AH9 SU ~ g.'°. ~ nee[ tyv~ .R.~.«.2~. it/.~/ '~ .~ a~/ 0 ~ CCri1~"¢[ gQ~Il~ ~~r~r~ t~A tt Piannin~ Depurtmen~ 36 NoY TO gcn~( f N.cnr Exhibit B t'lanning Dep~rtzne:~tt City of Central ~'oint 1 N T E R MEMO O F F I C E To: Tom Humphrey, Planning Director From: Lee Brennan, Public Works Director Subject. Memorandum Regarding Public Works Department Recommendations for the Tentative Land Partition and Zoning Variance Requests for property located at 644 Maple Street Date: July 25, 2000 It is the Public Works Department's recommendations that if the Planning Commission approves the tentative land partition and zoning variance request for the subject property, that the noted conditions are attached to the appravallvariancegronted: Maple and Seventh Street Improvements: Construct/reconstruct required driveway apron and any app[icabfe sidewalk sections (including curb and gutter sections, as applicable) to current City standards for portions of the subject property that border Maple and Seventh Streets. 2. AIIey_Improvements: if the Developer is going to take vehicular access to either of he two parcels from the alley, then it is recommended that the Developer be required to complete the required improvements to the alley to bring it to urban standards, including but not limited to paving (including street section), concrete alley apron, traffic delineation, and storm drainage infrastructure improvements. 3. Site Dralnage/5torrn Drain Plan: It is recommended that the developer design and implement a site drainagelstorm drain plan that corrects and enhances existing site drainage far the entire areas Hated an the site plan. This will require site drainage improvements to the entire tax lot. The current sheet flaw surface drainage from the properties onto the public rights-af-way or onto neighboring properties is unacceptable. The PWD review of this project will require a drainage plan which illustrates existing and future surface grades which illustrate surface drainage flow direction. The Developer shall verify that the roof drains or foundation drains are not connected to the sanitary sewer system, but which are connected to either discharge at the face of the curb, or into the storm drainage system. If the roof or foundation drains discharge to the sanitary sewer system, than the Developer wiq be required to modify the drains so that they discharge to a newly installed collection system that discharges at the face of the curb. 4. Driveways, Access Roads, and ParkingAreas: The Developer shall evaluate the strength of the native soils and determine the access roadldriveway section designs to 42 614 Af~i~~le S7rc•rf Tentatn~e I,n~d Parrrrra~a~l~inva•~ J ~«r't~rrac-~~ July .25. 100D Page 1 handle the expected loads {including fire equipment) to be traveled on these private drivewayslaccess roads. All driveways, access roads, and parking areas should either have asphalt or cement concrete surfaces. 5. Utility Easements: A 1 a-foot wide public utility easement (PUE) wilt be required along the subject property's frontages with Seventh Street. A P.U.E. will no# be required along Maple Street, as the 80-foot-wide right-of-way already accommodates this, based on the present and future projected development of Maple Street. 6. Cit Wafer Service Revision/U rode and Backflow Prevention Assemb! lnstalfation: As applicable, the Developer shall work with the City PWD on revising/upgrading the site's water service connections to comply with current City ordinances regarding water service and backflow prevention assembly installation #o each individual buildingllot. Approved backflow prevention assembly installation (at the Developer's expense) may be required directly behind all the Ci#y water service meters that service the proposed developments. Any new connections to the City`s water system to facilitate the proposed development shall be performed by the City at the Developer's expense. Generai Development Plans: Developer shall submit to the City's PWD for review and approval, engineered plans and specifications for all improvemen#s proposed for construction or modifications within the City or public rights-of-way and easements, or for connections to City infrastructure. Plans shall show all existing utilities and City facilities, existing contours, property lines, benchmarks and other physical site information needed for review. All plans submitted for PWD review shall be presented in a common engineering scale sized to fit on 24-inch by 36anch, D size drawing sheets. PWD requires 3 se#s of plans for review purposes. Public improvements include, but are not limited to, streets (including sidewalks, cuffs and gutters, ADA ramps, driveway aprons, and landscape buffers); alleys; storm drainage and sanitary sewer coilec#ion and conveyance systems; water distribution system {up to the service meter and including fire protection); and street lighting. All construction of public improvements shall conform to the City's PWD Standards, the conditions approved and stipulated by the Planning Commission, and other special specifications, details, standards, and/or upgrades as may be approved by the City Administrator or his designee prior to the approval of the construction plans for the proposed development. During construction, infrastructure or access changes proposed by the Developer shall be submitted in writing to the City PWD for approval prior to installation. ~provals: As applicable, Fire District No. 3 {fire hydrant access/location, fire flow capadty/line sizing, and emergency vehicle access} and Bear Creek Valley Sanitary ,~ ; 64~ Af<~>!e tifree( l~entatrve l,tlnd Parrrhr~n2wun,L 1'«rrnnc'c Jult' 15..2000 Pa fie _3 Authority {BCVSA, for sanitary sewers)written approval of construction plans shall be submitted to the City PWD prior to final construction plan review and approval by City PWD. 3. As-Builts: As applicable, Prior to approval and acceptance of the project, the Developer's engineer or surveyor shall provide the Public Works Department with "as- built" drawings. if feasible, the Developer's engineer or surveyor should provide the drawings in both a "hard copy" form (produced on Mylar~} and in a "digital" format compatible with AutoCAD°, or other form as approved by the Ci#y PWD. As-built drawings are to be provided to the City which provide "red-line" changes to fnal approved construction plans which identify the locations and or elevations (as appropriate) of actual installed items, including, but not limited to, invert, inlet, and rim or Gp elevations; spot elevations identified on drawings; water lines, valves, and fire hydrants; water and sewer lateral; modifications to street section; manhole and curb inlet; street light locations; other below grade utility lines; etc. Provide a "red-fine" hard copy (on Myfar®}, or an approved alternative format, of construction drawings, and if feasible, an acceptable AutoCAD® compatible drawing electronic fife to the City at completion of construction and prior to acceptance of public infrastructure facilities completed as part of the proposed development, or as otherwise approved by the City Administrator or his designee. 4. Elevations: All elevations used an the construction plans, and on temporary benchmarks shall be tied into an established City approved benchmark and be so noted on the plans. 5. Exi`sfin_g (nfrastructure: As applicable, field verify all existing infrastructure elevations and locations (i.e. pipe inverts, curb elevations, street elevations, etc.), to which the proposed development will connect into existing improvements, prior to final construction plan design and submittal for final approval. The accurate locations of any existing underground and above ground public infrastructure, and the location of the associated easements with these facilities, shall be accurately portrayed (both horizontally and vertically} on the construction plans. 6. Fill Placement: All fill placed in the development shall be engineered frll that is suitably placed and compacted in accordance with City PWD and Building Department standards, except for the upper 1.5-feet of fill placed outside of public rights-of-way and that does not underlie building, structures, or traveled vehicular access ways or parking areas. 7. Ufilify Plans: As built drawings shah reflect all utility locations; located both above and below ground. $_ Water Sysfem Cross Connecfiort Control. Devela{~er shall comply with Oregon 4~ S44 Afaple Srrecr Tenlalive Land Par(rlror~lonrn~; !'anaru•e July 25, 2000 Page 4 Health Division (OHD) and City requirements for cross connection control. 9. Wafer S, sY tem: Construction drawings shall include the size, type, and location of al! water mains, hydrants, valves, service connection, meter, service laterals, and other appurtenance details in accordance with City PWD Standards and as required by the City PWD. 10. Roof/Area Drains: All structures shall have roof drains, area drains, and/or craw! spaces with positive drainage away from the building. Roof drains shall not be directly connected to the public storm drain system. 11. Grading Plans: Grading plans should have original/existing grades and final grades plotted on the plan. Typically, existing grade contour lines are dashed and screened back, and final grade contour lines are overlaid on top of the existing grades and are in a heavier fine width and solid. Contour lines should be labeled with elevations. 12. Clear Asian Areas/Triangles. All driveway approaches of the proposed Development connecting to public roads ar alleys, and the a11ey connection to Seventh Street shall maintain the required sight vision triangles {25-feet, each side) as measured from the edge of the right-of-way to the center of the driveway. As applicable, this may require the removal of vegetation or structures to obtain the required clear sight-vision area. ~~ ~~,,C3ity ~ f Ceti tx-tl Point L1~,1~~~~T~ ccCss Ptannutg DeP~rtmc~tY EXHIBIT C PLANNING DEPARTMENT RECOMMENDED CONDITIONS OF APPROVAL 1. The approval of the Tentative Plan shall expire in one year on August 1, 2001 unless an application for final plat or extension has been received by the City. 2. The project ~xtust corrtply with all applicable focal, state and federal regulations. 3. The tentative and final plats shall depict utility easements requested by the City, BCVSA and WP Natural Gas. Any changes to utility layout including fire hydrants shall require subsequent approval by the respective service provider. 4. Pending the approval of the City Administrator, the applicant shall enter into a deferred improvement agreement for parcels 1 and 2 of the proposed partition. 39